LYYD-50KVA/150KV高壓耐壓成套裝置

簡要描述:LYYD-50KVA/150KV高(gao)(gao)壓(ya)(ya)(ya)(ya)耐壓(ya)(ya)(ya)(ya)成套裝置是在同類(lei)產(chan)品YDJ(G)型試(shi)驗變壓(ya)(ya)(ya)(ya)器的基礎上,按變壓(ya)(ya)(ya)(ya)器國家ZBK41006—89要求,經改(gai)進后生產(chan)的一種(zhong)(zhong)新型產(chan)品,本系列產(chan)品具有體積(ji)小、重量(liang)輕、結構緊湊、功(gong)能齊(qi)全、使用(yong)方便(bian)等特點(dian)。實(shi)用(yong)于電力、工礦、科研等部門,對(dui)各種(zhong)(zhong)高(gao)(gao)壓(ya)(ya)(ya)(ya)電氣設備(bei)、電氣元(yuan)件、絕(jue)緣材料進行工頻(pin)耐壓(ya)(ya)(ya)(ya)試(shi)驗和直流泄漏試(shi)驗,是高(gao)(gao)壓(ya)(ya)(ya)(ya)試(shi)驗中(zhong)*的儀(yi)器。

  • 產(chan)品(pin)型號:
  • 廠商(shang)性質(zhi):生產廠家
  • 更新時間:2020-05-21
  • 訪  問  量(liang):1336

產品介紹

LYYD-50KVA/150KV高壓耐壓成套裝置

二、LYYD-50KVA/150KV高壓耐壓成套裝置產品結構

    鐵芯為單框式。線圈采(cai)用同(tong)芯圓(yuan)筒多層塔式結(jie)構(gou),初級低(di)壓(ya)(ya)繞(rao)組(zu)繞(rao)在鐵芯上(shang),次級高(gao)壓(ya)(ya)繞(rao)組(zu)繞(rao)在低(di)壓(ya)(ya)繞(rao)組(zu)外(wai)側,這種同(tong)軸布置減少(shao)了(le)繞(rao)組(zu)間的藕合(he)損耗。高(gao)壓(ya)(ya)硅堆(dui)用特殊工(gong)藝封(feng)裝在套管(guan)內,產品(pin)的外(wai)殼制(zhi)成(cheng)與器芯配合(he)較佳的八角形結(jie)構(gou),整(zheng)體(ti)外(wai)型美觀大方。其內外(wai)部結(jie)構(gou)見(jian)圖(tu)1

產品型號含義

Y  D  Q   C  )—□ / 

                         圖1結構示意圖
  1-均壓球(qiu);2-硅堆短路桿(gan);3-高(gao)壓(ya)套管;4-油閥;5-殼體;67-調(diao)整電壓(ya)輸(shu)入ax端子;89-儀表測(ce)量(liang)EF端子;10-高壓尾X端(duan)子;11-變壓(ya)器外殼接地端;12-高壓(ya)輸出A端子;13-高(gao)壓整流硅堆;14-內部(bu)均壓環;15-變壓(ya)器鐵芯;16-初級低(di)壓繞組;17-測(ce)量儀(yi)表(biao)繞組;18-二次(ci)級高壓繞組;19-變壓器油(you)。

 

三、工作原理

    為單相(xiang)變壓器,聯結組(zu)標號(hao)II。單臺變壓(ya)器的工作過程,用(yong)交流220V10KVA以上(shang)為380V)電壓接入(ru)電源控制(zhi)箱(臺),經(jing)電源控制(zhi)箱(臺)內(nei)自藕調壓器(50KVA以上調壓(ya)器外附)調節0~200V10KVA以上0~400V)電(dian)壓(ya)(ya)至試(shi)驗變壓(ya)(ya)器(qi)的初級繞(rao)組,根據電(dian)磁感應原理(li),在變壓(ya)(ya)器(qi)高(gao)壓(ya)(ya)繞(rao)組可(ke)獲得試(shi)驗所需的高(gao)電(dian)壓(ya)(ya)。其(qi)工作原理(li)圖見圖2所示。

  1工作原理示意(yi)圖

                           圖工作原理(li)示意(yi)圖
在試驗變壓器中:ax為(wei)低(di)壓輸入端;A為高壓輸出端;EF為儀表測量端。
 2、單臺交直流兩用型變(bian)壓器工作原理見圖3。圖中(zhong)所示:高(gao)(gao)壓(ya)(ya)套管內(nei)裝有高(gao)(gao)壓(ya)(ya)硅(gui)堆(dui),串接(jie)在高(gao)(gao)壓(ya)(ya)回路中(zhong)作(zuo)高(gao)(gao)壓(ya)(ya)整流(liu),以獲(huo)得(de)直流(liu)高(gao)(gao)電壓(ya)(ya)。當用一短(duan)路桿將高(gao)(gao)壓(ya)(ya)硅(gui)堆(dui)短(duan)接(jie)時,可獲(huo)得(de)交流(liu)高(gao)(gao)電壓(ya)(ya),其狀態為交流(liu)輸(shu)出(chu)(chu);反之(zhi)在抽出(chu)(chu)短(duan)路桿時,其狀態為直流(liu)輸(shu)出(chu)(chu)。
3、三臺(tai)變壓器串激獲得更高(gao)電壓原理見圖4,串激變(bian)(bian)(bian)壓器有很大的優越性,因為整個(ge)試(shi)驗(yan)(yan)裝置(zhi)由多個(ge)單(dan)臺(tai)串激式變(bian)(bian)(bian)壓器組成,單(dan)臺(tai)試(shi)驗(yan)(yan)變(bian)(bian)(bian)壓器有著體積小(xiao)、重(zhong)量輕、便于運輸的特點,它既可(ke)以(yi)串接成高(gao)出幾倍的單(dan)臺(tai)試(shi)驗(yan)(yan)變(bian)(bian)(bian)壓器輸出電壓組合(he)使用,又(you)可(ke)以(yi)分開單(dan)獨使用。整套試(shi)驗(yan)(yan)裝置(zhi)投資小(xiao)、經濟實惠(hui)。圖3所示:在三臺(tai)串激式試(shi)驗變(bian)壓(ya)器串激使用中,單臺(tai)變(bian)壓(ya)器B1B2B3的(de)輸出電(dian)壓都是U,、二級的試驗變(bian)壓器內部都有(you)一個激磁繞組,分別為A1C1 和(he)A2C2。當控(kong)制電壓(ya)加在級(ji)變壓(ya)器B1的初級(ji)繞(rao)組a1x1上,激磁繞組A1C1給予試驗變壓器B2初級(ji)繞組供(gong)電,第(di)二級(ji)試驗(yan)變壓器B2的激磁繞(rao)組A2C2給(gei)試驗變壓器B3的初(chu)級繞組供電。由(you)于級變壓(ya)器B1的高壓尾及(ji)殼體接地,第二(er)、三(san)級的變壓器B2B3對地有絕緣支架的隔離,這(zhe)樣變壓器B1B2B3對地輸出電壓(ya)分別為1U2U3U

                 圖(tu)3:三臺高壓(ya)試驗變壓(ya)器串激工(gong)作原理示意圖(tu)
B1B2B3- 串激式高壓變(bian)壓器(qi);1U2U3U-各級對(dui)地電壓(ya);
PV- 高壓(ya)示值(zhi)表(KV); ZJ1ZJ2-絕(jue)緣(yuan)支架。

 

四、使用方法及(ji)注意事項(xiang)    

 1做工頻(pin)耐壓試驗使用接線方(fang)法見圖5。做(zuo)工頻(pin)耐壓(ya)試驗前,先(xian)根據試驗變(bian)壓(ya)器(qi)的額定容量選擇(ze)好(hao)限流(liu)電阻(zu),(水電阻)的(de)阻值(zhi),再根據(ju)被試品(pin)需加(jia)的(de)高(gao)(gao)壓(ya)電(dian)壓(ya)值(zhi)調整好放電(dian)球隙(xi)的(de)球間距,為(wei)了提高(gao)(gao)對被試品(pin)施加(jia)電(dian)壓(ya)的(de)測(ce)量(liang)精度(du),應(ying)在高(gao)(gao)壓(ya)側接入FRC阻(zu)容分壓(ya)器來測量電壓(ya)。

                      圖4:工頻耐壓試驗(yan)使用接線原理示意(yi)圖
R1R2- 限流電阻; Qx- 放電球隙; XJ- 被試(shi)品;
FRC- 阻容分壓器; V- 分壓器高壓表。 
按照圖4、結合圖2所(suo)進行的(de)工(gong)(gong)頻耐壓試(shi)驗(yan)接好工(gong)(gong)作(zuo)線路,試(shi)驗(yan)變壓器的(de)高壓繞阻的(de)X端(高壓(ya)尾(wei))、儀表測量繞組的F端、試驗(yan)變壓器的外殼(ke)以及(ji)電源控(kong)制箱(xiang)(臺)的外殼(ke)必(bi)須可靠(kao)接(jie)地。
用三臺(tai)試驗變(bian)(bian)壓器串激做工頻耐壓試驗時(shi)、第二、三級試驗變(bian)(bian)壓器的初級繞組(zu)X端(duan),儀表測量繞組的F端,以及(ji)高壓(ya)繞組的X端(高壓尾)均接(jie)本級試驗(yan)(yan)變(bian)壓器的(de)外殼(ke),第(di)(di)二(er)、三(san)級試驗(yan)(yan)變(bian)壓器的(de)主體必(bi)須放置在絕緣支(zhi)架上。除級以外、第(di)(di)二(er)、三(san)級試驗(yan)(yan)變(bian)壓器的(de)主體不要接(jie)地線(xian)。其接(jie)線(xian)方式(shi)見圖3所示。
 接(jie)電(dian)源前,電(dian)源控制(zhi)箱(臺)的調(diao)壓器必(bi)須調(diao)到零位(wei)。接(jie)通電(dian)源后(hou),綠色(se)指(zhi)示燈(deng)亮,按(an)一下啟動按(an)鈕,紅色(se)指(zhi)示燈(deng)亮,表(biao)示試驗變壓器已接(jie)通控制(zhi)電(dian)源,開始升(sheng)壓。
 從零位(wei)開始按(an)順(shun)時(shi)針方向(xiang)勻(yun)速旋轉調(diao)壓器(qi)手輪升壓。(升壓方式有:快速升壓法,即20S逐級升壓法,慢速(su)升壓法,即(ji)60S逐(zhu)級升(sheng)壓(ya)法,極慢(man)速升(sheng)壓(ya)法供選(xuan)用)電壓(ya)從(cong)零開始(shi)按選(xuan)定的(de)升(sheng)壓(ya)速度(du)升(sheng)到您所需額定試驗電壓(ya)的(de)75%后,再以每秒2%額定試(shi)驗電(dian)壓(ya)的速度升到(dao)您所需試(shi)驗電(dian)壓(ya),并密切注(zhu)意測(ce)量儀(yi)表(biao)的指示以及被(bei)試(shi)品(pin)的情況(kuang),被(bei)試(shi)品(pin)施(shi)加電(dian)壓(ya)的時(shi)間到(dao)后。應在數(shu)秒內勻(yun)速將(jiang)調壓(ya)器返回(hui),高壓(ya)降至(zhi)1/3試(shi)驗電壓(ya)以下,按(an)一(yi)下停止按(an)鈕,高壓(ya)、低壓(ya)輸出停止,然后切斷電源線,試(shi)驗完(wan)畢。

工頻耐壓試驗(yan)操作過程注意(yi)事項

1、試驗人員應做好責任分工,設定好(hao)試驗現(xian)場(chang)的(de)安全距離,仔細檢查好被試品及試驗變壓器的接地情況,并設有(you)專人監護安全及觀察(cha)被試(shi)品狀態(tai)工作。
2、被試品主要部(bu)位應清除干凈,保持干燥,以免損(sun)壞被試品和帶(dai)來試驗數值的誤差。
3、對大型設備的試驗,一般都應先進行(xing)試驗變壓器的空升試驗,即不接(jie)試品(pin)時升壓至試驗電壓,以便校對好(hao)儀(yi)表的指示精(jing)度,調整好(hao)放電球(qiu)隙(xi)的球(qiu)間距(ju)。
4、做耐壓(ya)試驗時(shi)升壓(ya)速度(du)不(bu)能過(guo)快,并防止突(tu)然加壓(ya),例如調(diao)壓(ya)器不(bu)在(zai)零位的突(tu)然合閘(zha),也不(bu)能突(tu)然斷(duan)電,一般應在(zai)調(diao)壓(ya)器降至零位時(shi)分閘(zha)。
5、在升壓或耐壓試驗(yan)過程中,如發現下列不正常情況,電(dian)(dian)壓、電(dian)(dian)流表指針擺(bai)動很大(da),被試品(pin)發(fa)出(chu)不正(zheng)常響聲,發現(xian)絕緣有燒焦或冒煙(yan)現(xian)象,應立即降壓,切斷電源,停止試驗并查明原因。
6、使用本產品做高(gao)壓試驗時,除熟悉本說明書外,還必須嚴格執行國家有關標準和操作規程。

2做直流(liu)耐壓和(he)泄漏試驗使(shi)用接(jie)線方法(fa)見圖5。由(you)于是交直(zhi)(zhi)流(liu)兩用變壓(ya)(ya)器(qi)(qi),應(ying)把高(gao)(gao)壓(ya)(ya)硅堆短路桿從套管中抽出,使變壓(ya)(ya)器(qi)(qi)為直(zhi)(zhi)流(liu)輸出狀態。做(zuo)直(zhi)(zhi)流(liu)泄漏試驗前(qian),先根(gen)(gen)據(ju)泄漏試驗中輸出端斷(duan)路電(dian)流(liu)不超過(guo)高(gao)(gao)壓(ya)(ya)硅堆的大(da)整流(liu)為宜,選擇好限流(liu)電(dian)阻(zu)(水電(dian)阻(zu))的阻(zu)值,再根(gen)(gen)據(ju)被試品對直(zhi)(zhi)流(liu)高(gao)(gao)壓(ya)(ya)波(bo)形的要求選擇好高(gao)(gao)壓(ya)(ya)濾波(bo)電(dian)容的電(dian)容值。為了(le)提高(gao)(gao)對被試品施加電(dian)壓(ya)(ya)的測量(liang)精度(du),應(ying)在高(gao)(gao)壓(ya)(ya)側接入(ru)FRC阻(zu)容分壓(ya)器來(lai)測(ce)量電壓(ya)。 

                      圖(tu) 5:直(zhi)流泄(xie)漏試驗使用接線(xian)原理示意圖(tu)
R- 限流電阻; C- 高壓濾波電容; XJ- 被試品; G- 硅堆短路桿;
FRC- 阻容分壓器;V- 分壓器高壓表;uA- 微安表;D- 高(gao)壓整流(liu)硅堆(dui)。
按照圖5、結合圖3所(suo)進行的直流泄(xie)漏試(shi)驗接(jie)好工(gong)作線(xian)路。試(shi)驗變(bian)壓器的高壓繞(rao)組的X端(高(gao)壓(ya)尾)、儀表測量(liang)繞組(zu)的端、試驗變壓器的外殼以(yi)及電源控制箱(臺)的外殼必須可靠接地。

                           接線(xian)原(yuan)理(li)圖

                                接(jie)線原理(li)圖
 接電(dian)源前、電(dian)源控制箱(臺)的(de)調(diao)壓器必須調(diao)到零位。接通(tong)電(dian)源后,綠色指示燈亮,按

一下(xia)啟動按鈕(niu),紅色指示燈亮,表示試驗變壓器已接通(tong)控(kong)制電源,開始(shi)升壓。
 從零位開始按(an)順時針方向勻(yun)速(su)旋轉調壓(ya)(ya)器手(shou)輪升(sheng)壓(ya)(ya)。(升(sheng)壓(ya)(ya)方式有:快(kuai)速(su)升(sheng)壓(ya)(ya)法即(ji)20S逐(zhu)級升壓法;慢速升壓法,即60S逐(zhu)級升壓(ya)(ya)法;級慢速升壓(ya)(ya)法供選用)電(dian)壓(ya)(ya)從零開始按選定(ding)的(de)(de)升壓(ya)(ya)速度升到您所需額定(ding)試(shi)(shi)驗電(dian)壓(ya)(ya)或額定(ding)直流(liu)電(dian)流(liu)下的(de)(de)參(can)考電(dian)壓(ya)(ya)。試(shi)(shi)驗中應嚴密注(zhu)意直流(liu)高壓(ya)(ya)表、泄漏電(dian)流(liu)表指(zhi)示以及被(bei)試(shi)(shi)品的(de)(de)情(qing)況。試(shi)(shi)驗完畢后(hou),應訊速均(jun)勻將高壓(ya)(ya)降至零位,按一下停止(zhi)按鈕,高壓(ya)(ya)、低(di)壓(ya)(ya)輸出停止(zhi),然后(hou)切(qie)斷電(dian)源。此時應用直流(liu)高壓(ya)(ya)放電(dian)棒給被(bei)試(shi)(shi)品及試(shi)(shi)驗裝(zhuang)置本身充(chong)分放電(dian)。

注意(yi)事項

1)試(shi)驗(yan)人(ren)員應做好責任分工,設定(ding)好現場的(de)安全距離(li),仔(zi)細(xi)檢查好被(bei)試(shi)品(pin)及(ji)試(shi)驗(yan)變壓(ya)器的(de)接地情況,并(bing)設有(you)專人(ren)監護安全及(ji)觀察被(bei)試(shi)品(pin)狀態工作。
2)被試品做試驗前,應(ying)拆(chai)除所(suo)有對(dui)外連線,并充分(fen)放電,主要部位應(ying)清除干凈,保持干燥,以(yi)免損壞被試品及帶來試驗數值的誤差。
3)對于大(da)容量試品(pin)(電(dian)容器、超(chao)長電(dian)纜等)試驗時(shi)(shi)應緩慢升壓(ya),防止被試品(pin)的充電(dian)電(dian)流過大(da)而燒壞(huai)微(wei)(wei)安表(biao)(biao),必要時(shi)(shi)應分級加壓(ya)分別讀(du)取各電(dian)壓(ya)下微(wei)(wei)安表(biao)(biao)的穩定(ding)讀(du)數(shu)。
4)試(shi)(shi)驗(yan)過程中,應嚴密監視被試(shi)(shi)品(pin)、微安表及試(shi)(shi)驗(yan)裝置等(deng),一旦(dan)發生閃爍(shuo)、擊穿(chuan)等(deng)現象應立即降壓,切斷(duan)電源(yuan),并查明原因。

五、配套選購(gou)產品(pin)

下列產品僅供(gong)選(xuan)擇(ze),購買時需另行計價。
1.KXJ系列電源控制箱 容量(liang):1KVA-5KVA、輸(shu)入電壓:220V
2.KZT系列電源控制臺(tai) 容量:10KVA~300KVA輸入電壓:220V380V
3.數字微安表:SWB-II
4.高壓濾(lv)波電容: 0.01MF40 ~ 100KV
5.高(gao)壓(ya)直流放電棒: FBR 70140210KV
6.放電(dian)球隙: Q50100150200250500
7.標準試油(you)杯: 400ml
8.折疊式手推車: 150300型(xing)
9.絕(jue)緣支(zhi)架: 50100200300400KV
10.阻容分壓(ya)器(qi): FRC 50100150200KV
11.高壓硅(gui)堆: 2DL150300450KV
12. 電(dian) 阻: 50100

六(liu)、主(zhu)要試驗設備的(de)選擇

1、變壓(ya)器
   其(qi)高壓(ya)(ya)側額定電壓(ya)(ya)應不小于(yu)被(bei)試(shi)品(pin)的(de)高試(shi)驗電壓(ya)(ya),額定電流不小于(yu)被(bei)試(shi)品(pin)的(de)大(da)電容電流。被(bei)試(shi)品(pin)的(de)電容電流和變壓(ya)(ya)器所需容量計算式為:

被(bei)試(shi)品電容量Cx可(ke)由交(jiao)流電橋(qiao)測出。常用的被(bei)試(shi)品(pin)電容量按表1選(xuan)取。

幾種(zhong)常(chang)用被試品(pin)的電容量(pF 1

 

2、調(diao)壓設備
  1)自(zi)藕調壓器(qi)。其調壓范圍廣、功率損(sun)耗小(xiao)、波形畸變小(xiao)、選擇這種調壓方式為(wei)好。自(zi)藕調壓器(qi)的(de)容(rong)量按0.75 ~ 1倍的試驗(yan)變壓器的容(rong)量(liang)選(xuan)擇,適用于容(rong)量(liang)為100KVA以(yi)下(xia)的變壓器的調壓。
  2)感(gan)應調(diao)壓(ya)(ya)器。其調(diao)壓(ya)(ya)范(fan)圍大,波形畸形小、但結構復雜、價格(ge)較貴,當變壓(ya)(ya)器的容量較大時(如100KVA以上)使用。
3、限流電阻(zu)
   限流(liu)電阻的作用(yong)是(shi),當被試品擊穿時,限制斷路電流(liu),從而保(bao)護(hu)變壓(ya)器(qi),防止故障的擴大。其數值(zhi)以高試驗電壓(ya)為準,按0.5 ~ 1 Ω / V(有效值)選擇(ze),限流電阻(zu)可用水(shui)(shui)電阻(zu)。注(zhu)意水(shui)(shui)不能(neng)充滿(man)玻(bo)璃管(guan),應(ying)留(liu)有余(yu)地,以防爆裂(lie)。
4、放電(dian)球(qiu)隙
   放電球隙的布置方式有垂(chui)直(zhi)和水平兩種,球隙間距S和(he)球的(de)直徑D的關(guan)系應保護在0.05D 0.5D范圍內,球(qiu)隙上(shang)的水電(dian)阻(zu)阻(zu)值一(yi)般按0.1 ~ 1Ω/V選取,設置(zhi)放電球(qiu)隙的(de)(de)目的(de)(de)是為了對重(zhong)要的(de)(de)被試品(pin)起保(bao)護作用(yong),可以將(jiang)由于(yu)誤操(cao)作或被(bei)試(shi)品擊(ji)穿引起的過電壓限制在(zai)允(yun)許的范圍內。

七、試驗變壓器技術指示(shi)

型號

容量

高壓電(dian)壓

高(gao)壓(ya)電流(liu)

低(di)壓(ya)輸入

變(bian)比

溫升(sheng)℃

(KVA)

(KV)

(mA)

電壓(V)

電(dian)流(A)

/

30分鐘

LYYD-1.5/50

1.5

50

30

200

7.5

500

10

LYYD-3/50

3

50

60

200

15

500

10

LYYD-5/50

5

50

100

200

25

500

10

LYYD-10/50

10

50

200

200

50

500

10

LYYD-15/50

15

50

300

200

75

500

10

LYYD-20/50

20

50

400

380

53

500

10

LYYD-30/50

30

50

600

380

79

500

10

LYYD-50/50

50

50

1000

380

12

500

10

LYYD-5/100

5

100

50

200

25

1000

10

LYYD-10/100

10

100

100

200

50

1000

10

LYYD-20/100

20

100

200

400

50

1000

10

LYYD-30/100

30

100

300

400

75

1000

10

LYYD-50/100

50

100

500

400

125

1000

10

LYYD-20/150

20

150

133

400

50

1500

10

LYYD-30/150

30

150

200

400

75

1500

10

LYYD-50/150

50

150

333

400

125

1500

10

LYYD-100/150

100

150

667

400

250

1500

10

LYYD-50/200

50

200

250

400

125

2000

10

LYYD-100/200

100

200

500

400

250

2000

10

LYYD-150/200

150

200

750

400

375

2000

10

LYYD-200/200

200

200

1000

400

500

2000

10

LYYD-300/200

300

200

1500

400

600

2000

10

LYYD-50/300

50

300

170

400

125

3000

10

LYYD-100/300

100

300

333

400

250

3000

10

LYYD-150/300

150

300

500

400

375

3000

10

LYYD-200/300

200

300

667

400

500

3000

10

LYYD-300/300

300

300

3000

500

600

3000

10

1、使(shi)用環境條件
環境溫度不高(gao)于+40℃、不(bu)低于—20℃;空氣相對濕(shi)度不大于90%;海拔(ba)高度不超過2000米;
2、工作電壓
電(dian)源控制箱(xiang)(臺)輸入電(dian)壓為工頻(pin)220V380V、相對誤差不(bu)超過±10%;(具(ju)體(ti)使用(yong)電壓(ya)根據用(yong)戶所(suo)定變壓(ya)器規格選取)
八、隨(sui)貨文件

產品說明(ming)書 1
產品出(chu)廠試(shi)驗報(bao)告 1
產品合格證 1
裝箱單(dan) 1

   上(shang)海(hai)徐吉電氣科技(ji)有(you)限公(gong)(gong)司(si)是專業從事電力系(xi)統高(gao)科技(ji)產(chan)品開發、生產(chan)、銷售的(de)(de)產(chan)業一體(ti)化公(gong)(gong)司(si)。公(gong)(gong)司(si)自(zi)成立以來開發出(chu)一系(xi)列直流接地(di)故障(zhang)定位裝置,該系(xi)列產(chan)品在現(xian)場的(de)(de)大量應用(yong)中獲(huo)得廣大用(yong)戶認可與肯定,總結(jie)以前各代(dai)(dai)產(chan)品的(de)(de)經驗和結(jie)合現(xian)場復雜的(de)(de)直流系(xi)統情況,開發出(chu)新一代(dai)(dai)現(xian)已廣泛應(ying)用于全國各個省市。

   能(neng)夠(gou)自適應各個電壓(ya)等級的(de)直流系統,配(pei)備高精度的(de)檢(jian)(jian)測(ce)(ce)鉗表,通過(guo)對信號的(de)高效、處理,大(da)大(da)提高了檢(jian)(jian)測(ce)(ce)范圍與抗(kang)干(gan)擾(rao)能(neng)力(li);采(cai)用了先進計(ji)算方法和模糊控制理論,將被檢(jian)(jian)測(ce)(ce)支路的(de)絕(jue)(jue)緣(yuan)程度以絕(jue)(jue)緣(yuan)指數(shu)和波形(xing)的(de)形(xing)式表示出(chu)來,充分體(ti)現(xian)了人(ren)工智能(neng)的(de)優越性;對于接(jie)地(di)點位置的(de)判斷(duan)以及(ji)接(jie)地(di)阻抗(kang)值的(de)計(ji)算,它們更是擁(yong)有準(zhun)(zhun)確(que)的(de)判斷(duan)能(neng)力(li)和快速的(de)運算能(neng)力(li),每次檢(jian)(jian)測(ce)(ce)都(dou)能(neng)夠(gou)指出(chu)接(jie)地(di)點的(de)位置和接(jie)地(di)電阻的(de)阻值,從而快速、準(zhun)(zhun)確(que)地(di)實現(xian)包(bao)括環路在內(nei)的(de)接(jie)地(di)檢(jian)(jian)測(ce)(ce)。

   不僅解決了直流系統(tong)間接(jie)接(jie)地(di)、非金(jin)屬(shu)接(jie)地(di)、環(huan)路接(jie)地(di)、正(zheng)負(fu)同時(shi)接(jie)地(di)、正(zheng)負(fu)平衡接(jie)地(di)、多點接(jie)地(di)等疑難故障的(de)準確定位,并且還(huan)能準確的(de)顯示系統(tong)電壓、對地(di)電壓、接(jie)地(di)阻值(zhi)、支路接(jie)地(di)阻抗值(zhi),真正(zheng)解決了運行及檢修(xiu)人員的后顧之憂。

本裝(zhuang)置以系統安全為首要前提,按行業(ye)標準(zhun)的高要求,以可靠(kao)的低頻信(xin)號方(fang)式(shi)進行檢測(ce),并在現場進行了大量的實際應用,對系統無(wu)任何影響。

當(dang)你對LYDCS-3300 便攜式直流接地定位(wei)儀進(jin)行操作(zuo)(zuo)前,請(qing)認真閱讀本用戶手(shou)冊,并嚴格遵守本手(shou)冊的(de)要(yao)求,任(ren)何不正(zheng)確的(de)操作(zuo)(zuo)都可能(neng)導致人身傷(shang)害或設備(bei)損(sun)壞。

LYDCS-3300 便攜(xie)式直流接地定位儀是一種(zhong)高精(jing)密儀器,設備(bei)內部不含有任何(he)維(wei)修配件。在設備(bei)出現故障(zhang)時,請(qing)盡快進行(xing)維(wei)護,切勿擅自維(wei)修,這(zhe)樣可能擴大(da)故障(zhang)范(fan)圍及影響設備(bei)以后的售后服(fu)務(wu)。

使用要求:

產品技術規格(ge)要求必須嚴格(ge)遵守。

只(zhi)有接(jie)受(shou)培訓并仔細閱(yue)讀(du)本手冊的人員,才能對設備進行操作(zuo)、使用(yong)。

1.2 有(you)關配線:

本裝置配有與直(zhi)流系統連接的三芯(xin)電(dian)纜,該(gai)電(dian)纜在出廠前(qian)經嚴格測試,符(fu)合(he)安全使(shi)用,請勿私自使(shi)用未經認可的電(dian)纜替換,如有缺失,請。

有(you)關(guan)操作(zuo):

雖裝置(zhi)不含高壓部分,但需與直流系(xi)統連接,系(xi)統電(dian)(dian)壓會危及人身安全,必須遵守電(dian)(dian)力操作(zuo)規程,做好人體絕緣措施。

當(dang)裝置(zhi)發生故障時,請及(ji)時使裝置(zhi)脫離系(xi)統,并(bing)盡快對設備進(jin)行維護,切勿(wu)繼續(xu)使用。

有關(guan)廢棄:

廢(fei)棄的元、部(bu)件,請按照工業廢(fei)物處理。

我們會對每(mei)一(yi)(yi)位涉及到裝置使用的(de)人(ren)員進行一(yi)(yi)定的(de)技術培(pei)訓(xun),并且(qie)使每(mei)一(yi)(yi)位相關(guan)人(ren)員對本(ben)手冊的(de)安(an)全(quan)內容(rong)進行深入的(de)學習和理解,所有的(de)相關(guan)人(ren)員必(bi)須對一(yi)(yi)般的(de)安(an)全(quan)規則和標(biao)準的(de)低(di)壓電(dian)氣設備使用安(an)全(quan)有一(yi)(yi)個全(quan)面的(de)了解。此外還必(bi)須嚴格遵守本(ben)手冊介紹的(de)安(an)全(quan)知識。

LYDCS-3300是采用新微計算機技(ji)術的新產品。在硬(ying)件上(shang),信號發生(sheng)器(qi)、檢測器(qi)雙(shuang)層抗(kang)分布電容設計,消除分布電容影響(xiang);配(pei)置(zhi)精度(du)高、線性度(du)好的(de)傳(chuan)感器,直流信(xin)號檢測靈(ling)敏(min)度(du)高達0.01mA,有效保(bao)證了(le)(le)(le)采集(ji)的(de)(de)數據的(de)(de)準確(que);在軟件上,利用了(le)(le)(le)模(mo)糊(hu)控制(zhi)理論和通信的(de)(de)噪(zao)聲理論,并依據直(zhi)流系統的(de)(de)特(te)點(dian)優化了(le)(le)(le)算(suan)法(fa),即使系統有大分布電容的(de)(de)干(gan)(gan)擾(rao)、電磁(ci)脈沖(chong)干(gan)(gan)擾(rao)和其它噪(zao)聲干(gan)(gan)擾(rao)的(de)(de)影響,也能準確(que)地(di)(di)判斷(duan)出接(jie)地(di)(di)故(gu)(gu)障點(dian),為接(jie)地(di)(di)故(gu)(gu)障的(de)(de)查找提供了(le)(le)(le)有力的(de)(de)保(bao)障。可對各種直(zhi)流接(jie)地(di)(di)故(gu)(gu)障進行查找和定位,并計算(suan)該支(zhi)路接(jie)地(di)(di)阻(zu)抗值。

2.1 產器特(te)點:

  LYDCS-3300具有自適(shi)應(ying)各(ge)個(ge)電壓等(deng)級(ji)的(de)直流(liu)系統,具有智(zhi)能(neng)(neng)化的(de)接(jie)地(di)(di)點(dian)方向判斷功能(neng)(neng),能(neng)(neng)夠快(kuai)速、準(zhun)確地(di)(di)定(ding)位出多點(dian)接(jie)地(di)(di)、高阻接(jie)地(di)(di)、正(zheng)負(fu)極接(jie)地(di)(di)、環路接(jie)地(di)(di)等(deng)各(ge)種接(jie)地(di)(di)故障,

2.2 友好(hao)的人機界(jie)面:

LYDCS-3300 人機界面簡潔、清晰,操作(zuo)簡單(dan),形(xing)象的絕緣指數顯示和(he)實時的

波(bo)形(xing)顯示,直觀地反應出各(ge)檢測支路的(de)絕緣程度及接地故障點方向。

2.3 高精度(du)檢測:

LYDCS-3300 采用高精(jing)度傳感單元(分辨率達0.01mA),具有(you)精度(du)高、線性好、檢測范(fan)圍(wei)寬(kuan),能實現對多點接(jie)地、高阻(zu)接(jie)地的定位。

2.4 抗干擾能力(li)強:

LYDCS-3300能(neng)有效排除交直流串電故障(zhang)(zhang),不(bu)受接地故障(zhang)(zhang)點距(ju)離限制,通過(guo)軟

硬(ying)件(jian)上的(de)(de)合理設計,能抗系統各種復雜紋波干擾,實(shi)現(xian)對接地點的(de)(de)定位。

2.5 輸出功(gong)率小:

   LYDCS-3300根(gen)據直流(liu)系統現場的實際情況(kuang),信號發生(sheng)器可智能式(shi)產生(sheng)1.0

5.0mA 的信號電流,大(da)功率(lv)小于0.05W,保(bao)障直流系統的安全、可靠運行。

2.6 人性化的外觀設計:

LYDCS-3300 采(cai)用工程(cheng)力學(xue)的外(wai)形設計,使用舒適,重量(liang)輕巧,攜帶方(fang)便。

2.7 嚴格選用優良的元器(qi)件,科學的生產管理(li),保證裝置的高靠性。

本(ben)裝置由信號發生(sheng)器、檢測器、鉗(qian)表三部分(fen)組(zu)成(cheng)

3.1 裝(zhuang)置的內(nei)部工作原理:

3.1.1 信號(hao)發生器(qi)內部工(gong)作原理(li):

3.1.2 檢(jian)測器內(nei)部工作原理:

3.2 接地檢測(ce)原理(li):

3.2.1 信(xin)號發生(sheng)器檢(jian)測(ce)原(yuan)理:

當直流系統發(fa)(fa)生(sheng)(sheng)接(jie)地(di)(di)故障(zhang)(zhang)或絕(jue)緣降低時(shi),信(xin)號(hao)(hao)發(fa)(fa)生(sheng)(sheng)器自動對直流系統進(jin)行分(fen)析,顯示(shi)系統的(de)電(dian)(dian)壓等級、正負極對地(di)(di)電(dian)(dian)壓、接(jie)地(di)(di)故障(zhang)(zhang)的(de)極性和(he)(he)接(jie)地(di)(di)總阻抗。同時(shi)向直系統發(fa)(fa)出安全的(de)低頻檢測信(xin)號(hao)(hao),通過輸出信(xin)號(hao)(hao)的(de)智能反饋,對信(xin)號(hao)(hao)實(shi)施(shi)控制,進(jin)一步確(que)保輸出信(xin)號(hao)(hao)的(de)安全性和(he)(he)提高接(jie)地(di)(di)故障(zhang)(zhang)定位(wei)的(de)準確(que)。

3.2.2 檢測器檢測原理:

  檢測器通(tong)過高精度(du)鉗(qian)表感應各回路(lu)(支路(lu))的接地電(dian)流信(xin)(xin)號(發生器發出的接地電(dian)流信(xin)(xin)號),并顯(xian)示接地故(gu)障(zhang)程(cheng)度(du)和方向(xiang),順著對接地電(dian)流信(xin)(xin)追蹤查找,終定位出故(gu)障(zhang)點(dian)。

適用直流系統電壓:

220V±15%110V±10%48V±10%24V±10%,或用戶定制其它(ta)電壓等級;

抗對地分布(bu)電(dian)容范圍:系(xi)統對地總(zong)電(dian)容≤100uF,單(dan)支路對(dui)地電(dian)容≤5uF

信(xin)號發生器(qi)輸出功(gong)率 0.05W

信號發生器(qi)測(ce)量(liang)范圍:

母線對(dui)地電阻測量:01000 KΩ

系統對地容(rong)抗測(ce)量:01000 KΩ

檢測器精(jing)度:< 10A

檢測器對接地故障定位范圍:

220V直流(liu)系統:  500 KΩ

110V直流系統:  250 KΩ

48V直流系統(tong):  0  125KΩ

環境溫度:-35  +50

相對濕度:≤ 95% (不結露)      

總質(zhi)量(liang):   2 kg  

外形尺寸(包裝箱):380x280x120mm

LYDCS-3300 便攜式(shi)直流接地定位儀采用(yong)大屏(ping)幕的漢(han)化液晶和LED發光管顯示,通過按鍵(jian)實施操作(zuo)。

5.1 面板外觀與布局

5.1.1 信(xin)號發(fa)生(sheng)器(qi)的外觀與布局(ju):

信號(hao)發(fa)生器正面(mian)外觀(guan)與布局:

“電(dian)源"燈亮(liang)      說明(ming)信號發生器(qi)已(yi)開啟(qi)。

“正(zheng)常(chang)"燈亮(liang)      說明系統(tong)無接地故障。

“正極接地(di)"燈亮  說明系統發(fa)生正極(ji)接地故障。

“負極接地"燈(deng)亮(liang)  說明系統發生負極接地故障(zhang)。

“開(kai)關"按鍵      信號發生器的電源開關鍵

信號發生器背面與布局(ju):

說明:

滑動開關(guan)位置(zhi)位于:

左(1檔):信(xin)(xin)號發生器處于自動(dong)監(jian)測(ce)功能,時(shi)刻對直流系(xi)統進行(xing)監(jian)測(ce)并及實時(shi)更(geng)示(shi)系(xi)統相關參數的顯示(shi)。主要(yao)用途(tu)是查找系(xi)統出現一(yi)般(ban)性接地故障。信(xin)(xin)號強度為1.4mA 

中(2檔):信號(hao)發生(sheng)器(qi)處(chu)于自動監測功(gong)能,時刻對(dui)直流系(xi)統進(jin)行監測并及實時更示系(xi)統相關參數的顯示。主要用途是查找(zhao)系(xi)統出現一般(ban)性(xing)接地故障。(該檔為出廠(chang)默(mo)認(ren)設置)信號(hao)強(qiang)度(du)為6mA 

右(3檔):信號(hao)發生器處于接(jie)地故(gu)(gu)障自(zi)鎖定功能(neng),當直流系(xi)統(tong)一經出現(xian)接(jie)地故(gu)(gu)障,發生器只對系(xi)統(tong)進行(xing)一次分析后,自(zi)動(dong)鎖定狀檢(jian)測結果(guo)和發送信號(hao)狀態,不(bu)對系(xi)統(tong)參數(shu)的(de)變化進行(xing)跟蹤。主要用途是(shi)查(cha)找系(xi)統(tong)的(de)間歇(xie)性(xing)接(jie)地和接(jie)地阻抗頻繁(fan)跳變等(deng)特殊接(jie)地故(gu)(gu)障。信號(hao)強度為6mA

5.1.2 檢測器(qi)的外觀與布(bu)局:

檢測器正面外觀與布(bu)局:

“電源燈(deng)"燈(deng)亮 說明檢測(ce)器已開啟。

“電源(yuan)"按鍵 是檢測器的(de)電源開關(guan)鍵(jian)。

“功能切換"按鍵 是(shi)檢測器在(zai)功能選(xuan)擇界面下(xia)的“快速檢測" 、“完整(zheng)檢測" 和“在線檢測"三個功(gong)能之間的(de)切(qie)換鍵(jian)。任何時候按功(gong)能鍵(jian),跳轉到功(gong)能選擇界面(mian)。

“檢測"按鍵 當檢測(ce)(ce)器選定其中一種檢測(ce)(ce)功能時,每按一次(ci)“檢測(ce)(ce)"鍵(jian),檢測(ce)(ce)器就進行(xing)一次(ci)新(xin)的(de)測(ce)(ce)試。

檢(jian)測器背面與布局:

5.1.3 鉗(qian)表的(de)外觀與布局:

LYDCS-3300鉗表

“鉗頭" 用于鉗(qian)住被測的電纜。

“方向(xiang)標示" 標示接地故障(zhang)參考方向。

“鉗表開合按(an)鍵" 按(an)下打開鉗表(biao),松開合上鉗表(biao)。

“電源燈"亮(liang)  說明檢(jian)測(ce)器與(yu)鉗表已連接,鉗表和檢(jian)測(ce)器均(jun)處于(yu)開啟狀(zhuang)態。

“鉗表輸出電纜" 是(shi)鉗(qian)表把采樣信號輸出到檢測(ce)器的連(lian)接電(dian)纜。

5.2 液(ye)晶屏顯示界面

5.2.1 信號(hao)發生器(qi)液晶屏顯示界(jie)面:

信號發生器具有自適應不同電(dian)壓等級(ji)的直流(liu)系統功能(neng),在系統無接地故障時,“正常"指示(shi)燈亮(liang)。液(ye)晶顯(xian)示(shi)屏顯(xian)示(shi)直流(liu)系統母線電(dian)壓、正極對地電(dian)壓、 負(fu)極對地電壓及系統對地絕緣(yuan)值。顯示界面如下圖:

(直流系統無接地故障時信號發(fa)生(sheng)器顯(xian)示界面)

直流(liu)系(xi)(xi)統(tong)有接(jie)地(di)故障(zhang)時,信(xin)號發生器(qi)自動(dong)判斷接(jie)地(di)故障(zhang)極(ji)性。如系(xi)(xi)統(tong)正(zheng)接(jie)地(di),信(xin)號發生器(qi)“正(zheng)極(ji)接(jie)地(di)"指(zhi)示(shi)燈亮(liang),如系(xi)(xi)統(tong)負(fu)接(jie)地(di),“負(fu)極(ji)接(jie)地(di)"指(zhi)示(shi)燈亮(liang),同時液晶(jing)顯(xian)(xian)(xian)示(shi)屏(ping)顯(xian)(xian)(xian)示(shi)系(xi)(xi)統(tong)母線(xian)電(dian)(dian)壓(ya)、正(zheng)極(ji)對(dui)(dui)地(di)電(dian)(dian)壓(ya)、負(fu)極(ji)對(dui)(dui)地(di)電(dian)(dian)壓(ya)、系(xi)(xi)統(tong)對(dui)(dui)地(di)絕(jue)緣總阻(zu)抗。顯(xian)(xian)(xian)示(shi)界面如下圖:

(直(zhi)流(liu)系統(tong)發生正極28KΩ時信(xin)號發(fa)生器顯示(shi)界面)

5.2.1 檢測器(qi)液晶屏顯示界面:

當被(bei)檢(jian)測(ce)的回(hui)路(lu)(支(zhi)路(lu))無接地(di)故障時,檢(jian)測(ce)測(ce)器顯示界(jie)面如下圖:

  

如選(xuan)擇(ze)“快速檢測(ce)"功能,當被檢測(ce)的回路(支路)有(you)接(jie)地(di)故障時,檢測(ce)測(ce)器(qi)顯示(shi)界面如下:(其中(zhong),如顯示(shi)“鉗(qian)(qian)表正(zheng)向(xiang)接(jie)地(di)"表示(shi)接(jie)地(di)故障點(dian)與鉗(qian)(qian)表標(biao)示(shi)箭頭(tou)方向(xiang)*,如顯示(shi)“鉗(qian)(qian)表反(fan)(fan)向(xiang)接(jie)地(di)"表接(jie)地(di)故障點(dian)與鉗(qian)(qian)表標(biao)示(shi)箭頭(tou)方向(xiang)相反(fan)(fan))

 

                         ;        (檢測結(jie)果(guo)顯示(shi)圖)

如選擇“完整檢(jian)測"功能(neng),當被檢(jian)測的回路(lu)(支路(lu))有接(jie)地(di)故(gu)障(zhang)時(shi),檢(jian)測測器顯示(shi)界面(mian)如下:(其中(zhong),如顯示(shi)“正向(xiang)接(jie)地(di)"表(biao)(biao)示(shi)接(jie)地(di)故(gu)障(zhang)點與鉗(qian)表(biao)(biao)標示(shi)箭頭方(fang)向(xiang)*,如顯示(shi)“鉗(qian)表(biao)(biao)反向(xiang)接(jie)地(di)"表(biao)(biao)示(shi)接(jie)地(di)故(gu)障(zhang)點與鉗(qian)表(biao)(biao)標示(shi)箭頭方(fang)向(xiang)相反)

如選擇“在(zai)線檢測"功能,檢測器將不停的掃(sao)描回(hui)路(支路)接地情(qing)況,用以對較(jiao)復(fu)雜回(hui)路情(qing)況進行判斷。

6.1 設備使用前的準備

6.1.1檢查檢測(ce)器(qi)的(de)電池:由于裝置使用(yong)時間間隔(ge)較長(chang),容(rong)易造成電池電量不足(zu),影響檢測(ce)準確性,甚至使(shi)檢(jian)測工(gong)作無法正常進(jin)行,因此在使(shi)用裝置前請檢(jian)查(cha)電池的電量是否滿(man)足工(gong)作要求,否則請更換(huan)電池。

6.1.2把鉗(qian)表(biao)輸出電纜與檢(jian)測(ce)器(qi)連接(jie)(jie),開啟檢(jian)測(ce)器(qi),以(yi)檢(jian)驗鉗(qian)表(biao)與檢(jian)測(ce)器(qi)聯接(jie)(jie)狀況(kuang),如鉗(qian)表(biao)上“電源(yuan)"燈亮(liang),表(biao)示鉗(qian)表(biao)與檢(jian)測(ce)器(qi)聯接(jie)(jie)正(zheng)常,否則請(qing)檢(jian)查電纜接(jie)(jie)接(jie)(jie)頭是否已(yi)正(zheng)確、可靠地接(jie)(jie)在檢(jian)測(ce)器(qi)上。

6.1.3把信(xin)號發生器連接(jie)(jie)入直流系(xi)統(tong)。信(xin)號發生器通過三(san)芯電(dian)纜正確、可(ke)靠地連接(jie)(jie)在(zai)系(xi)統(tong)母線靠近蓄電(dian)池(chi)側。

注:信號(hao)發生器信號(hao)連接線(xian)(xian)(xian):紅夾(jia)子(褐色(se)(se)線(xian)(xian)(xian))接系(xi)統母線(xian)(xian)(xian)正極,黑夾(jia)子(藍色(se)(se)線(xian)(xian)(xian))接系(xi)統母線(xian)(xian)(xian)負極,黑夾(jia)子(黃綠(lv)色(se)(se)線(xian)(xian)(xian))接系(xi)統地線(xian)(xian)(xian)。確認發生器正確并(bing)可靠地與(yu)系(xi)統連接好。

   6.1.4在使用LYDCS-3300前(qian)建(jian)議關閉直流系統正在(zai)運行的在(zai)線接地監測裝置(zhi),這樣更有利于接地故障(zhang)的準確、快速定(ding)位。

6.2 設備的使用操作

    當直流系統(tong)(tong)發生(sheng)接地故(gu)障時,打開信(xin)號(hao)發生(sheng)器(qi)(qi)電源開關,此時信(xin)號(hao)發生(sheng)器(qi)(qi)自動適應系統(tong)(tong)電壓等級,分析系統(tong)(tong)絕緣狀況,并把分析結果通過(guo)液晶(jing)顯示屏(ping)和LED燈(deng)分別顯示,此時再利用檢測器依次對各(ge)個可能的支路進行檢測,直(zhi)到定位出所有接地故障點(dian)為止。

使用(yong)檢測器進(jin)行接進(jin)故障(zhang)定(ding)位操(cao)作方法及(ji)實例介紹。

6.2.1 檢(jian)測器上(shang)的鉗表鉗在被(bei)測回路(支路)時,請確認鉗表口(kou)已(yi)*閉(bi)

合,否(fou)則會(hui)影響檢測(ce)結果的準確性。由(you)于鉗(qian)(qian)表精度非(fei)常高(gao),鉗(qian)(qian)好(hao)被測(ce)回(hui)路后,請待鉗(qian)(qian)表靜止后再(zai)按(an)動檢測(ce)器的“檢測(ce)"鍵開始檢測(ce)。

6.2.2 鉗單根:當正(zheng)、負極電(dian)纜不(bu)能同時被鉗表(biao)鉗住時,采(cai)用“鉗單根"

的檢測方法,如是(shi)正極(ji)接地(di),將鉗(qian)表鉗(qian)在(zai)正極(ji)電纜上,再(zai)按一下檢

測器上(shang)的“檢測"鍵進(jin)行檢測,如(ru)是負極接(jie)地,則(ze)鉗(qian)在負極電纜(lan)上(shang),

再按一(yi)下(xia)檢(jian)(jian)測器上的&ldquo;檢(jian)(jian)測"鍵進行(xing)檢(jian)(jian)測。

對電纜進(jin)行接(jie)地故障進(jin)行檢(jian)測時,接(jie)地方向判別如(ru)下(xia)圖:

6.2.3 鉗雙(shuang)根:為了(le)避(bi)免(mian)被測回路(支路)電流過大而超過鉗表量程和進

一步降(jiang)低直流系統其(qi)它紋波(bo)干擾,提(ti)高檢測(ce)器檢測(ce)結果的精度,請

盡(jin)量用鉗表(biao)同時鉗住回(hui)路(支路)的(de)正、負極(ji)電纜(lan)進(jin)行檢測。

6.2.4 鉗多根:當有多根電(dian)纜在扎一(yi)起時,在鉗表能同時鉗住的情況下(注:

鉗(qian)表口必(bi)須*閉(bi)合),可以(yi)同(tong)時鉗(qian)住多根電纜一起進行檢(jian)測,如檢(jian)

測器(qi)判(pan)(pan)斷為“非(fei)接(jie)地"則說(shuo)明該(gai)扎電纜沒有接(jie)地故障,如(ru)檢測器(qi)判(pan)(pan)

斷為(wei)“接地(di)(di)",則(ze)說(shuo)明該扎(zha)電(dian)纜其中有一回路或(huo)多(duo)回有接地(di)(di)故障,此

時必須將該(gai)扎電纜分(fen)開(kai)用(yong)二(er)分(fen)法進檢測(ce)排查,找出有接(jie)地故障回路,

再沿(yan)著(zhu)檢(jian)測器提示的接(jie)地故(gu)障(zhang)方向往下(xia)檢(jian)測,直到定位(wei)出接(jie)地故(gu)障(zhang)

點為(wei)止。

6.2.5 由于(yu)現場電纜(lan)回路復雜多樣,根據實際情況靈活運用鉗單(dan)根、鉗雙

根、鉗(qian)多(duo)根方(fang)法進行(xing)檢測(ce),提(ti)高檢測(ce)效率,縮短定位(wei)故(gu)障(zhang)時間。

6.2.6 檢測波形析法:由于有(you)的直流系(xi)統含有(you)較復(fu)雜的紋(wen)波和干擾(rao)信號,

對檢測器(qi)造成一定的影響,我們除了可以(yi)利用鉗雙根法來克服干擾

外(wai),還可以利用檢測(ce)器(qi)在檢測(ce)過(guo)程(cheng)中實時顯示的(de)信號(hao)(hao)波形(信號(hao)(hao)波

形為周期6秒的矩形波)來(lai)進行輔助(zhu)判(pan)斷(信號波形請(qing)參考第5

5.2.1的顯示(shi)界面介紹)。

6.2.7 單(dan)點接地故障實(shi)例介紹:

如上圖,當直流系的分支路2電(dian)纜發生接(jie)地障時,把信號發生器接(jie)在系統(tong)母線(xian)靠近蓄電(dian)池側。

當信號發生器判斷出直流系統的接地總阻(zu)抗值并(bing)向系統發送檢(jian)測信號時,開(kai)始使用檢(jian)測器對系統進行(xing)接地故障檢(jian)測。

如圖所示,我們利(li)用檢(jian)測(ce)器(qi)上的鉗表先對主支(zhi)路ABC點依次(ci)檢測,由于被檢測信號(hao)只經過支(zhi)路C流向接地電阻的,故在檢測(ce)支路AB時,檢測器均判斷為(wei)“非(fei)接地",說明這兩個(ge)支路絕緣狀況良好,當檢測支路的(de)C點時,檢測器(qi)判斷(duan)該支路有接地故障,并(bing)會通“絕緣程度條"(0100)來表(biao)示(shi)接(jie)地(di)故(gu)障(zhang)的嚴重程度(du),同時也(ye)會顯示(shi)接(jie)地(di)故(gu)障(zhang)所處(chu)的方(fang)向(xiang)(判斷方(fang)法(fa)見6.2.2)。沿著檢(jian)測器所判斷接地方向繼(ji)續(xu)檢(jian)測,在檢(jian)測分支路(lu)D點時,檢測(ce)器判(pan)斷為(wei)“非接地",檢測(ce)分支(zhi)路(lu)E點時,檢(jian)測器判斷為有接地故障(zhang),繼續(xu)往下檢(jian)測,當檢(jian)測到F點時,檢測器判斷為&ldquo;非(fei)接地(di)"則可確(que)定接地(di)故障點在(zai)EF點之間,通不繼縮短EF間(jian)的檢測點,直到終找出具體(ti)的接地(di)故障點為止。

6.2.8 兩(liang)點(dian)、多點(dian)及正負極同時接(jie)地故障檢測方法:

兩(liang)(liang)點(dian)(dian)(dian)接(jie)(jie)地(di)(di)檢測(ce)(ce)(ce)方法:當直流系統(tong)發生兩(liang)(liang)點(dian)(dian)(dian)接(jie)(jie)地(di)(di)故障(zhang)(zhang)時(shi),如兩(liang)(liang)點(dian)(dian)(dian)接(jie)(jie)地(di)(di)故障(zhang)(zhang)的(de)(de)(de)阻(zu)抗(kang)值(zhi)較(jiao)(jiao)(jiao)接(jie)(jie)近(jin),則按檢測(ce)(ce)(ce)的(de)(de)(de)先后順(shun)序依(yi)次檢測(ce)(ce)(ce)出(chu)各個(ge)接(jie)(jie)地(di)(di)故障(zhang)(zhang)點(dian)(dian)(dian)的(de)(de)(de)位置(zhi);如兩(liang)(liang)點(dian)(dian)(dian)接(jie)(jie)地(di)(di)故障(zhang)(zhang)的(de)(de)(de)阻(zu)抗(kang)值(zhi)相(xiang)差比較(jiao)(jiao)(jiao)大時(shi),檢測(ce)(ce)(ce)器先檢測(ce)(ce)(ce)出(chu)接(jie)(jie)地(di)(di)較(jiao)(jiao)(jiao)嚴重的(de)(de)(de)接(jie)(jie)地(di)(di)故障(zhang)(zhang)點(dian)(dian)(dian),在排除該點(dian)(dian)(dian)故障(zhang)(zhang)后,信(xin)號發生再(zai)重新分析系統(tong)絕緣(yuan)狀況,并顯(xian)示出(chu)另(ling)(ling)一點(dian)(dian)(dian)的(de)(de)(de)接(jie)(jie)地(di)(di)阻(zu)抗(kang)值(zhi),此時(shi)再(zai)用檢測(ce)(ce)(ce)器對另(ling)(ling)一接(jie)(jie)地(di)(di)故障(zhang)(zhang)點(dian)(dian)(dian)進行檢測(ce)(ce)(ce)、定位。具體(ti)的(de)(de)(de)操(cao)作方法與單點(dian)(dian)(dian)接(jie)(jie)地(di)(di)操(cao)作方法相(xiang)似(si)(參見6.2.7)。

多點接(jie)(jie)地(di)故(gu)(gu)障檢測(ce)方(fang)法:當系統發生多點接(jie)(jie)地(di)故(gu)(gu)障時,接(jie)(jie)地(di)故(gu)(gu)障的定位操作(zuo)方(fang)法與兩點接(jie)(jie)地(di)故(gu)(gu)障操作(zuo)方(fang)法相(xiang)似。

正(zheng)(zheng)負(fu)極(ji)(ji)同(tong)時接地(di)(di)(di)(di)檢(jian)測方法(fa):當系統發(fa)生正(zheng)(zheng)負(fu)極(ji)(ji)同(tong)時接地(di)(di)(di)(di)故障(zhang)(zhang)(zhang)時,如正(zheng)(zheng)極(ji)(ji)接地(di)(di)(di)(di)故障(zhang)(zhang)(zhang)較(jiao)嚴(yan)重,信號發(fa)生器(qi)先分析正(zheng)(zheng)極(ji)(ji)的(de)接地(di)(di)(di)(di)狀況(kuang),并先判斷為正(zheng)(zheng)極(ji)(ji)接地(di)(di)(di)(di),再用檢(jian)測器(qi)對正(zheng)(zheng)極(ji)(ji)接地(di)(di)(di)(di)故障(zhang)(zhang)(zhang)點進(jin)行(xing)定位(wei)。在排(pai)除(chu)正(zheng)(zheng)極(ji)(ji)接地(di)(di)(di)(di)故障(zhang)(zhang)(zhang)后,信號發(fa)生器(qi)再分析負(fu)極(ji)(ji)的(de)接狀況(kuang),并判斷為負(fu)極(ji)(ji)接地(di)(di)(di)(di),再用檢(jian)測器(qi)對負(fu)極(ji)(ji)接地(di)(di)(di)(di)故障(zhang)(zhang)(zhang)點進(jin)行(xing)定位(wei)和排(pai)除(chu)。具體的(de)操(cao)作方法(fa)與(yu)單(dan)點接地(di)(di)(di)(di)操(cao)作方法(fa)相似(參見6.2.7)。

6.2.9 環路接地故障檢測方法:

如圖所示(shi):直流(liu)系統(tong)的(de)支路2與支(zhi)路3組(zu)成環路,分支路1接在(zai)(zai)環路上,此時在(zai)(zai)分支路1的電纜上發生(sheng)了接地(di)故障(zhang)。

由圖分(fen)析可知:信(xin)號(hao)(hao)發(fa)生器發(fa)出的檢(jian)測信(xin)號(hao)(hao)會分(fen)別(bie)從支路2和支(zhi)路3兩個方向(xiang)流向(xiang)接(jie)地故(gu)障點,路徑分別是:從BàDàFà接地故障(zhang)點、CàEàFà接地故障點。

在信號發生器對系統(tong)分析完成(cheng)后,我們使用(yong)檢測(ce)(ce)器先從主支路開(kai)始檢測(ce)(ce),依次對ABC三個進檢(jian)測點檢(jian)測,檢(jian)測器判斷A檢(jian)測(ce)點(dian)為非(fei)接(jie)地(di)、B檢(jian)測點(dian)為接地、C檢測點(dian)為接地,并(bing)提示BC檢(jian)測點下方有接(jie)地故障(zhang),接(jie)著(zhu)我們分別(bie)順著(zhu)檢(jian)測器提示(shi)的(de)接(jie)地方向在D點和E點繼續檢測,在D點檢(jian)測時(shi),檢(jian)測器提示電(dian)電(dian)纜右側有接地(di)故障(zhang),在E點檢測(ce)時,檢測(ce)器提示電纜左(zuo)側有接地故障(zhang),根據對DE點(dian)檢(jian)測的接地方向提(ti)示判斷,我們可(ke)以(yi)確定是在DE間發生了接(jie)地故障。再檢測接(jie)在(zai)DE間的(de)分支路(lu)1的(de)F點(dian)時,檢測器(qi)再次提示此(ci)處電(dian)纜下方有接地,然后(hou)繼續對(dui)G點(dian)進行檢測,檢測器提示該點(dian)為非接(jie)地,由此,我們可能肯定接(jie)故障點(dian)就在F點與(yu)G點之間,通過不斷縮F-G間的檢測(ce)距(ju)離(li),直到終定位出具體(ti)的接(jie)地故障點為止。

隨著(zhu)我國(guo)經(jing)濟(ji)的(de)(de)(de)飛速發展,直流(liu)系統(tong)及其負載日新(xin)月異,由此增加了(le)直流(liu)系統(tong)發生接(jie)(jie)地(di)故(gu)障時的(de)(de)(de)復雜性。限于篇幅,以上(shang)只列舉出其中(zhong)的(de)(de)(de)幾(ji)種(zhong)(zhong)比較常見的(de)(de)(de)接(jie)(jie)地(di)故(gu)障的(de)(de)(de)檢測方法,雖然無法包含(han)所有(you)現場(chang)實(shi)際接(jie)(jie)地(di)現象,但我們可以根據(ju)接(jie)(jie)地(di)故(gu)障與(yu)現場(chang)實(shi)際情況結(jie)(jie)合,堅持以人為(wei)(wei)本,設備(bei)為(wei)(wei)輔的(de)(de)(de)思路,靈活組合運用(yong)以上(shang)幾(ji)種(zhong)(zhong)檢測方法、積極利(li)用(yong)自身的(de)(de)(de)經(jing)驗(yan)結(jie)(jie)合實(shi)踐開拓新(xin)的(de)(de)(de)檢測方法來更快(kuai)、更地(di)*接(jie)(jie)地(di)故(gu)障。同時我們也真誠希望能與(yu)廣大用(yong)戶交流(liu)直流(liu)接(jie)(jie)地(di)檢測的(de)(de)(de)心得和(he)經(jing)驗(yan),總結(jie)(jie)出更多有(you)效(xiao)、便捷的(de)(de)(de)檢測方法,為(wei)(wei)我國(guo)電力安全做出更大的(de)(de)(de)貢獻(xian)!

中(zhong)國上海(hai)測(ce)試中(zhong)心(上海(hai)市計量(liang)測(ce)試技(ji)術研究(jiu)院(yuan))是(shi)政府按照集中(zhong)投入大型科學儀(yi)器,開展科學技(ji)術研究(jiu),為社會(hui)綜合性測(ce)試技(ji)術服務而(er)建立的技(ji)術機構。1984年,被科技部定(ding)為(wei)guo家級測(ce)試中(zhong)心(xin),并(bing)要求逐(zhu)步建設(she)成為(wei)“分析(xi)測(ce)試方法的(de)研究中(zhong)心(xin),儀器(qi)分析(xi)技術(shu)人(ren)員的(de)培訓中(zhong)心(xin),分析(xi)測(ce)試的(de)技術(shu)服務中(zhong)心(xin)"。

上海市(shi)計(ji)量測試技術研究院是(shi)上海市(shi)政(zheng)府計(ji)量行(xing)政(zheng)部(bu)門依法(fa)設置的國(guo)家(jia)法(fa)定計(ji)量檢定機(ji)構(gou),也(ye)是(shi)國(guo)務(wu)院計(ji)量行(xing)政(zheng)部(bu)門批(pi)準建立的華東地區法(fa)定計(ji)量檢定機(ji)構(gou)——華東國(guo)家(jia)計(ji)量測試中(zhong)(zhong)心(xin)(xin),同時也(ye)是(shi)國(guo)家(jia)科(ke)技部(bu)批(pi)準建立的guo家(jia)級分(fen)析測試中(zhong)(zhong)心(xin)(xin)——中(zhong)(zhong)國(guo)上海測試中(zhong)(zhong)心(xin)(xin)。國(guo)家(jia)計(ji)量器具質(zhi)量監督檢驗中(zhong)(zhong)心(xin)(xin)(上海)是(shi)在(zai)上海市計(ji)量(liang)測試技術研究院基(ji)礎(chu)上籌(chou)建(jian)的,是(shi)國內的在(zai)地(di)方計(ji)量(liang)機構基(ji)礎(chu)上籌(chou)建(jian)的綜合性(xing)guo家級(ji)計(ji)量(liang)器(qi)具(ju)質檢(jian)機構。
      掛靠我(wo)院的國家金銀制品(pin)質量監督檢驗(yan)中心(上海)、上(shang)海(hai)(hai)(hai)市(shi)環(huan)(huan)境保(bao)護(hu)產(chan)品(pin)質量(liang)監(jian)督(du)檢(jian)驗(yan)總(zong)站、上(shang)海(hai)(hai)(hai)市(shi)電子產(chan)品(pin)質量(liang)監(jian)督(du)檢(jian)驗(yan)站、上(shang)海(hai)(hai)(hai)市(shi)貴金屬寶玉石質量(liang)監(jian)督(du)檢(jian)驗(yan)站、上(shang)海(hai)(hai)(hai)市(shi)信(xin)息系(xi)統及(ji)產(chan)品(pin)質量(liang)監(jian)督(du)檢(jian)驗(yan)站、上(shang)海(hai)(hai)(hai)市(shi)氣體化(hua)(hua)工(gong)產(chan)品(pin)質量(liang)監(jian)督(du)檢(jian)驗(yan)站,同時也是上(shang)海(hai)(hai)(hai)市(shi)計量(liang)測試(shi)技(ji)術(shu)研究院設立的(de)專門從事(shi)環(huan)(huan)保(bao)產(chan)品(pin)、電子產(chan)品(pin)、貴金屬寶玉石、信(xin)息系(xi)統及(ji)產(chan)品(pin)、氣體化(hua)(hua)工(gong)產(chan)品(pin)檢(jian)測的(de)技(ji)術(shu)部門。
      上海市計量(liang)測(ce)試(shi)技術研究院、華東國家(jia)(jia)計量(liang)測(ce)試(shi)中(zhong)(zhong)心、中(zhong)(zhong)國上海測(ce)試(shi)中(zhong)(zhong)心、國家(jia)(jia)計量(liang)器具(ju)質(zhi)量(liang)監督檢驗中(zhong)(zhong)心(上海)、國家金銀制品質(zhi)量監督檢驗(yan)中心(上海)通過(guo)(guo)了(le)中國國家認(ren)證(zheng)認(ren)可(ke)監督管理(li)委員會(hui)的(de)計(ji)量(liang)認(ren)證(zheng)。同時,我院(yuan)通過(guo)(guo)了(le)國家認(ren)監委的(de)食品檢驗機構的(de)計(ji)量(liang)認(ren)證(zheng)。掛(gua)靠我院(yuan)的(de)各上海(hai)市產(chan)品質(zhi)量(liang)監督檢驗站通過(guo)(guo)了(le)上海(hai)市質(zhi)量(liang)技術監督局的(de)計(ji)量(liang)認(ren)證(zheng)。計(ji)量(liang)認(ren)證(zheng)范(fan)圍可(ke)通過(guo)(guo)&ldquo;機構名(ming)稱(cheng)"和“產(chan)品/產品(pin)類別"、“項(xiang)目/參數"進行查詢(xun)。

按照(zhao)建立的初衷和科(ke)技(ji)部(bu)的要求,中心始終把服(fu)務社會、服(fu)務企(qi)業作(zuo)為自己的一(yi)項神圣使(shi)命,為上(shang)海(hai)的科(ke)技(ji)創新、經(jing)濟(ji)發展提供了重要技(ji)術支撐。多年來,為上(shang)海(hai)塊石(shi)英電(dian)子表的誕(dan)生、桑塔那轎車國產(chan)化、風云衛(wei)星(xing)、大橋斜拉(la)索、秦山核電(dian)站、浦東機(ji)場等多個重大工程、大型(xing)企(qi)業提供了測試服(fu)務,并制(zhi)定或參與制(zhi)定了一(yi)批產(chan)品(pin)、系(xi)統等方面的技(ji)術標準,起到了技(ji)術平(ping)臺的作(zuo)用。

上海徐吉電(dian)(dian)氣科技有限公司主要從(cong)事高(gao)壓檢(jian)測試驗設備、電(dian)(dian)力自動(dong)化設備、微機繼電(dian)(dian)保(bao)護測試系統(tong)、變電(dian)(dian)站在線檢(jian)測設備等諸多電(dian)(dian)力檢(jian)測產品(pin)(pin)(pin)研發、生產與(yu)銷(xiao)售。產品(pin)(pin)(pin)品(pin)(pin)(pin)種多、規(gui)格全、技術先進,得到行業內(nei)的諸多好評。

上海(hai)徐吉電(dian)氣科(ke)技有限公司通過了GB/ISO-9001:2000-ISO9000-2000質(zhi)量體系認證,產(chan)品(pin)多次通過上(shang)海(hai)市計量測(ce)試研(yan)究院(yuan)鑒定,成為電(dian)(dian)力行業(ye)(ye)品(pin)牌。公司(si)在全(quan)國(guo)二十多個省(sheng)、市、區建立了銷售網絡和(he)售后服務網絡,產(chan)品(pin)服務于各大電(dian)(dian)力局、電(dian)(dian)廠及國(guo)內許(xu)多大型企業(ye)(ye)。
上(shang)海徐吉(ji)電氣科技有限公司常(chang)年致力于新技術(shu)和(he)新產品的研(yan)制與(yu)開發(fa),不斷將新技術(shu)用于產品改(gai)進(jin)和(he)新品開發(fa)上(shang)。在設(she)計和(he)制造上(shang)始終追求產品的高(gao)安全(quan)性(xing)、高(gao)可靠性(xing)、高(gao)品質質量性(xing)。
上海徐吉電氣科(ke)技有(you)限公司(si)一貫(guan)奉行誠信(xin)務(wu)實的精(jing)神(shen),不(bu)斷努力(li),開拓進取,視電力(li)檢測(ce)為己任。以(yi)科(ke)技求(qiu)發展,以(yi)質(zhi)量求(qiu)生存,以(yi)服(fu)務(wu)求(qiu)信(xin)譽,以(yi)管理求(qiu)效益(yi),為客(ke)戶和社會(hui)提供優(you)良的服(fu)務(wu)。
       公司理念:遠見(jian)卓(zhuo)識、超越創新!
       信譽宗旨:品質磐如(ru)石,承諾硬如(ru)金(jin)!

上海(hai)徐(xu)吉電氣科技有限公(gong)司是中國大(da)的測(ce)試儀(yi)器、檢(jian)測(ce)設備生(sheng)產廠家之一。本(ben)公(gong)司于國外(wai)品牌(pai)建立了長(chang)期的戰(zhan)略性合作關系,通(tong)過(guo)與世(shi)界(jie)大(da)的測(ce)繪GPS公司——美國Trimble公司的戰略合作,將GPSRTKVRS、全站儀、水準(zhun)儀、3D激(ji)光掃描儀等產品推廣給中國測繪用戶,并將海(hai)洋測量(liang)產品、機(ji)械(xie)控制產品和SCS900等先(xian)進的設備引入(ru)中國。從2003年(nian)起,上海(hai)徐吉成為美國Trimble公司大(da)的分銷商之一(yi),在(zai)中國(guo)的*高達35%,成為名(ming)副其實(shi)的(de)(de)(de)者。先進的(de)(de)(de)產品(pin)、優質的(de)(de)(de)服(fu)務和與(yu)客戶長期的(de)(de)(de)緊密(mi)合作,使上海徐吉成為中國(guo)測繪行業響(xiang)亮的(de)(de)(de)品(pin)牌。與(yu)Trimble的合作,還延伸至OEM板和GIS等領域。

上海徐吉不僅為用戶提供先進的GPS設備,還根據中國國情,為用戶提供(gong)量身打(da)造的系統集成、技(ji)術和(he)服務(wu),如:GPS基(ji)站網(wang)絡解決方(fang)案、基(ji)于PDAGPS手簿的應用(yong)軟件(jian)開(kai)發、GPS數據自動化(hua)后處理軟件(jian)開發(fa)、大壩和橋梁(liang)等高精(jing)度工(gong)程項目的系(xi)統(tong)解決方(fang)案(an),并在石油勘(kan)(kan)探(tan)開發(fa)、鐵路勘(kan)(kan)探(tan)、公路建設、土(tu)地規劃、城市勘(kan)(kan)測、水利開發(fa)、電力工(gong)程等方(fang)面擁有豐富的測繪工(gong)程實踐經驗(yan)。

富有戰(zhan)略眼(yan)光的(de)上海徐吉將業務(wu)拓(tuo)展到(dao)水(shui)工業行(xing)業,開始(shi)了與的(de)離(li)心機制(zhi)造商——德國(guo)Westfalia離心機公司的(de)合作。短(duan)短(duan)四年的(de)時間,徐(xu)吉公司在污泥固液(ye)分離領域,實現了從零(ling)到的(de)飛躍。2003年以來,上海徐吉的(de)*一直(zhi)保持地位,達到了30%,成為(wei)中國大(da)的進口離(li)心脫(tuo)水設備供應商。

2004上海徐吉憑借其在水工業(ye)行業(ye)的優(you)勢(shi)資源,與(yu)世界(jie)上大的管(guan)道檢測設備(bei)制造商&mdash;—德國IBAK公司和美國著名的Aquatech疏通車制造商(shang)建立了(le)(le)又一(yi)個強(qiang)強(qiang)聯手的(de)合作關系,成功拓(tuo)展了(le)(le)其(qi)在水工業行業的(de)業務領域。

陸地(di)資(zi)源(yuan)日益匱乏(fa),海洋必將成(cheng)為未來(lai)經濟(ji)新的(de)增(zeng)長點。上海徐吉利用(yong)其在測繪、導航、通信、授時和(he)水工業行業的(de)優勢(shi)地(di)位,圈定(ding)了海洋作為其大展宏圖(tu)的(de)下一個目標。

非凡(fan)的(de)(de)(de)成就來源于(yu)非凡(fan)的(de)(de)(de)團隊(dui)!以人(ren)為本(ben)的(de)(de)(de)理念使(shi)上(shang)海(hai)徐吉電(dian)氣科(ke)技(ji)有限公司凝聚了強(qiang)大的(de)(de)(de)人(ren)力(li)資源,極富戰略眼光的(de)(de)(de)市場(chang)開(kai)發隊(dui)伍、專業高效的(de)(de)(de)管理團隊(dui)和精明快捷的(de)(de)(de)銷(xiao)售隊(dui)伍,鑄(zhu)就了上(shang)海(hai)徐吉過去的(de)(de)(de)輝煌,并將成就麥(mai)格(ge)集團未來的(de)(de)(de)理想。

將(jiang)*的(de)(de)產品引(yin)入中國,研制、開發、配套適合中國用戶的(de)(de)*集成(cheng)系(xi)統和(he)服(fu)務,將(jiang)國內質量高成(cheng)本低的(de)(de)產品引(yin)入市(shi)場,是上海(hai)徐(xu)吉(ji)電氣科技有限公司的(de)(de)長期(qi)宗旨。*滿足于現狀,使(shi)上海(hai)徐(xu)吉(ji)電氣科技緊緊抓住了歷史賦予的(de)(de)大好機(ji)遇!

徐吉的服務(wu)

售前服(fu)務(wu)

提供技術咨詢:我們確(que)保24小(xiao)時內(nei)回答您(nin)所提出(chu)的任何技(ji)術(shu)問題(ti);

提供產品資料(liao):我(wo)們確保24小(xiao)時內將您(nin)所需要的所有技術資料寄出;

提供合理報價:我們(men)確保24小(xiao)時內對您所要(yao)求的設備合理報價;

提供(gong)考察接待:我們確保隨時接待您(nin)的考察,并為您(nin)提供(gong)各(ge)項便(bian)利服務(wu)。

售中服務

我們確保無(wu)論合同大小,都將認真、公正(zheng)、嚴謹、誠信地對待每份合同;

我們確保守時、保質保量(liang)、嚴格(ge)執行合同各項(xiang)要求;

我們確保按合(he)同的要求為您提供送貨、安(an)裝、調試、現場培訓等;

我們確(que)保按您的(de)(de)要(yao)求(qiu)簽定嚴密(mi)的(de)(de)、科學的(de)(de)《產品(pin)技術協議》。

售后服務(wu)

售后:

如果(guo)您的產品需要維護,或(huo)咨(zi)詢技(ji)術方面(mian)的問(wen)題,請您直接(jie)我們(men)的。

售后服務承諾:自(zi)購(gou)貨(huo)之日起,凡(fan)在正(zheng)常使用中出現任何質量問(wen)題,本公司保證三個月內包換,一年內免(mian)費(fei)維修,終身維護,軟件免(mian)費(fei)升級(ji)。

健全客戶(hu)檔案(an):設備(bei)檔案(an)齊全,軟件升(sheng)級(ji)更新及(ji)時,每(mei)次(ci)服務(wu)活動均(jun)詳細記(ji)錄在案(an),可(ke)隨(sui)時查詢。每(mei)年統計(ji)客戶(hu)設備(bei)的(de)維(wei)修(xiu)記(ji)錄,為客戶(hu)作出合理建議。

高素(su)質的團隊:本公(gong)司擁有(you)一(yi)支高學(xue)歷、高素(su)質的技術團隊,流程科學(xue)化、管理規范化。從接(jie)聽到,徐吉人親切和氣,全心全意(yi)為客戶服務!

上海(hai)徐(xu)吉電(dian)氣(qi)科技有限(xian)公(gong)司為電(dian)力(li)施(shi)工(gong)單(dan)位(wei)總(zong)結出申報國家(jia)承(cheng)試電(dian)力(li)四級資質所(suo)需設備配置清單(dan),根據各事業、電(dian)力(li)施(shi)工(gong)單(dan)位(wei)的(de)性質不同(tong)選型的(de)種(zhong)類有所(suo)區別,請仔細(xi)閱讀,不詳細(xi)之處可以我(wo)公(gong)司,我(wo)公(gong)司會有專業人做出解(jie)答,所(suo)申報的(de)產品明細(xi)清單(dan)如下:

   0.1HZ超低(di)頻耐壓試驗裝置;變(bian)(bian)頻串并聯(lian)諧振(zhen)耐壓試驗裝置,無局(ju)放試驗變(bian)(bian)壓器(qi),交(jiao)流耐壓試驗變(bian)(bian)壓器(qi);高壓電(dian)抗(kang)器;大電流發生器;干式試驗變壓器;直流高壓發生(sheng)器(qi);發(fa)電機(ji)通(tong)水直流高壓發(fa)生器;變頻介質損耗測試儀;回路電阻測(ce)試儀;直(zhi)流電阻測試儀(yi);全自動變比測(ce)試(shi)儀;氧化(hua)鋅避雷器測(ce)試(shi)儀;互感器綜合校驗儀;變(bian)頻大(da)地(di)網(wang)接地(di)阻抗測試儀;大型(xing)地(di)(di)網接(jie)地(di)(di)阻抗測試儀;高壓開關動特性測試儀;變(bian)壓器油(you)微(wei)量(liang)水分測試儀、油(you)酸值測試儀、油(you)色譜分析(xi)儀、油(you)粘稠度測試儀、油(you)燃點測試儀、SF6氣體微量水(shui)分測試(shi)儀(yi)、SF6氣體密(mi)度繼電器校(xiao)驗儀(yi)、精密(mi)露點儀(yi)(微水(shui)儀(yi))、電纜(lan)故(gu)障測(ce)(ce)試(shi)(shi)(shi)儀(yi)、交(jiao)流(liu)采樣變送(song)器校(xiao)驗裝(zhuang)置、礦用雜散(san)電流(liu)測(ce)(ce)試(shi)(shi)(shi)儀(yi)、蓄電池容(rong)量恒流(liu)放電測(ce)(ce)試(shi)(shi)(shi)儀(yi)、感(gan)應式軸承加熱器、真(zhen)空度測(ce)(ce)試(shi)(shi)(shi)儀(yi);微機繼電(dian)保護(hu)測試儀;(工頻(pin)(pin)、變頻(pin)(pin))介質損耗測試儀;絕緣油介電強度(du)測試儀;多功能真空濾油(you)機;變壓(ya)器(qi)有(you)載開關(guan)測試儀;高壓無線核相(xiang)儀(yi);變壓器電參數測試(shi)儀三倍(bei)頻(pin)(pin)電(dian)源發(fa)生器(qi);多倍(bei)頻(pin)(pin)電(dian)源發(fa)生器(qi);變壓器(qi)容量測(ce)試儀(yi)(yi)、變壓器(qi)變比(bi)組別測(ce)試儀(yi)(yi)、發(fa)動機交流阻(zu)抗測(ce)試儀(yi)(yi)、高(gao)壓斷路器(qi)機械特性測(ce)試儀(yi)(yi);模擬斷路器校驗儀;伏安特性測試(shi)儀;絕緣電阻測試儀;數字式高壓(ya)兆(zhao)歐表;接地(di)電阻測試儀;三相相序表;三相(xiang)電(dian)能表(biao)現場校驗(yan)儀(yi)(yi)(yi)、三相(xiang)相(xiang)位伏安表(biao)、防(fang)雷原件測(ce)(ce)試(shi)儀(yi)(yi)(yi)、絕(jue)緣板絕(jue)緣制品、變頻法工(gong)頻線路(lu)參數測(ce)(ce)試(shi)儀(yi)(yi)(yi)、三相(xiang)電(dian)容(rong)電(dian)感(gan)測(ce)(ce)試(shi)儀(yi)(yi)(yi)、電(dian)容(rong)電(dian)橋(qiao)測(ce)(ce)試(shi)儀(yi)(yi)(yi)、無線高(gao)壓變比(bi)測(ce)(ce)試(shi)儀(yi)(yi)(yi)、高(gao)壓驗(yan)電(dian)器、高(gao)壓放(fang)電(dian)棒、SF6氣體(ti)泄漏(lou)(lou)(lou)監控報警系(xi)統、高壓電(dian)(dian)(dian)纜在線(xian)監測(ce)(ce)系(xi)統、微機消(xiao)諧裝置(zhi)、容性(xing)(xing)設備介(jie)質損(sun)耗帶電(dian)(dian)(dian)測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)系(xi)統、漏(lou)(lou)(lou)電(dian)(dian)(dian)保護器(qi)測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、漏(lou)(lou)(lou)電(dian)(dian)(dian)流監控記(ji)錄儀(yi)(yi)(yi)(yi)(yi)(yi)、母線(xian)槽、滑觸線(xian)、電(dian)(dian)(dian)熱管其他(ta)工控系(xi)統及裝備。串聯諧振耐壓裝置(zhi)、大電(dian)(dian)(dian)流發(fa)生器(qi)、升流器(qi)、試(shi)(shi)(shi)(shi)(shi)驗變(bian)壓器(qi)、直(zhi)流高壓發(fa)生器(qi)、變(bian)比測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、直(zhi)流電(dian)(dian)(dian)阻測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、繼電(dian)(dian)(dian)保護測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、高壓開關測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、伏安特性(xing)(xing)測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、真空度測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、氧化(hua)鋅(xin)避雷器(qi)測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、回路電(dian)(dian)(dian)阻測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、變(bian)壓器(qi)電(dian)(dian)(dian)參數測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、變(bian)壓器(qi)容量(liang)測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、局部放電(dian)(dian)(dian)測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、超(chao)低頻發(fa)生器(qi)、電(dian)(dian)(dian)容電(dian)(dian)(dian)感(gan)測(ce)(ce)試(shi)(shi)(shi)(shi)(shi)儀(yi)(yi)(yi)(yi)(yi)(yi)、介(jie)損(sun)儀(yi)(yi)(yi)(yi)(yi)(yi)、電(dian)(dian)(dian)能表校(xiao)驗儀(yi)(yi)(yi)(yi)(yi)(yi)、色譜(pu)儀(yi)(yi)(yi)(yi)(yi)(yi)、核相儀(yi)(yi)(yi)(yi)(yi)(yi)。

 

10KV35KV發、供電系統(tong)繼保測試(shi)及高電壓(ya)試(shi)驗設備(bei)的裝置

序(xu)號

試驗設備(bei)

試驗項目(mu)

技術指標

參(can)考(kao)

1

微機繼電(dian)保護測試儀(單相)

各種常規單相試驗

AC:0-10A0-100A

DC:0-1500mA0-5A

0-100V   0°-360°

能(neng)模(mo)擬110KV及以下電壓等級試驗

2

微機繼電保護測試儀(yi)

(三相)

微(wei)機型等(deng)復雜(za)保(bao)護(hu)試(shi)驗

三相(xiang)電流:3×(0-30A,

四(si)相電壓:4×(0-120V

7對開入+三對開出,

帶(dai)載功率:5A:≥75VA 30A:400VA

輸(shu)出時間:<10A:連(lian)續輸出(chu) 20A>6030A:>10秒(miao)表 精度:0.2

滿足DL/T624-1997要求

3

模擬式(shi)兆歐(ou)表數字(zi)式(shi)兆歐(ou)表

絕緣(yuan)電(dian)阻測量

500-2500V 10000MΩ

短路電流不小(xiao)于1mA

4

直流高壓(ya)發生器

直流耐壓和直流泄(xie)漏測量

60KV/2Ma(10kv) 120kv/2mA(35kv)

 

波紋系(xi)數不大于(yu)1%

5

試驗變壓器(qi)、控制臺、調壓器(qi)

工頻(pin)高壓(ya)試驗裝置(zhi)

5KVA/50KV(10kv)25KVA/100KV(35kv)

波紋失真度小于5%

6

變(bian)壓器直流(liu)電阻測試(shi)儀

變壓器(qi)直流電阻測量(liang)

1A  1mΩ-200Ω 0.2

測量(liang)電流根據變壓(ya)器(qi)容(rong)量(liang)確定

7

變壓器變比測試(shi)儀

變壓(ya)器變比測試(shi)儀(yi)

測量范圍(wei):1-100 準確度:0.2

 

8

變壓器(qi)損(sun)耗參數測(ce)試儀

變(bian)壓(ya)器空負載短路試驗

測量準確度不小于0.5

 

9

介質(zhi)損耗測(ce)試儀(yi)或高壓電橋(qiao)

介損及電容量(liang)測量(liang)

tgδ:±5% 電容電量:±3%

 

10

變壓器有載(zai)分接開(kai)關測試儀(yi)

變壓器有載調壓開(kai)關(guan)測試(shi)

時間(jian)測量(liang)范(fan)圍:0-250ms 準確度(du):±0.1%

電阻(zu)測量范圍(wei):0.1-20Ω 準確度:±1.0%

 

11

回路電阻測(ce)試(shi)儀

導電回路接觸電阻(zu)測量

準(zhun)確(que)度:0.51uΩ-2mΩ

輸出(chu)電流(liu)不小于100A

12

高壓開(kai)關機械特性測試儀

高(gao)壓開關機械(xie)動作特性測量

準確度:±0.1%

 

13

真空(kong)度測試儀(yi)

真(zhen)空開關(guan)真(zhen)空度(du)測(ce)量

 

 

14

斷口耐壓試驗裝置

真(zhen)空開(kai)關斷(duan)口耐(nai)壓(ya)試(shi)驗(yan)

電壓測量準確度(du):3.0

 

15

絕緣油介電強度測試(shi)儀(yi)

絕緣油介電強度(du)試驗

電壓測量(liang)準(zhun)確度(du):3.0

穩態(tai)測量準確度(du):1.5

16

無局放(fang)變(bian)壓(ya)器

局放試驗

2KVA/50KV

 

17

局部放電(dian)檢測儀

局部放(fang)電測量(liang)

頻率:10-300HZ 準確度:10

 

18

高壓(ya)分(fen)壓(ya)器(qi)測量系統

試驗電(dian)壓(ya)測量

準(zhun)確度:AC 1.0 DC 0.5級(ji)

 

19

互感器綜合特(te)性測(ce)試儀

互感(gan)器變比(bi)、CT伏安特性測試(shi)

準確度:0.2

 

20

氧化鋅避雷器(qi)測(ce)試儀(yi)

氧化鋅(xin)避雷器測(ce)量

可(ke)測量(liang)阻性電(dian)流(liu)(峰值(zhi)(zhi))、電(dian)容電(dian)流(liu)(峰值(zhi)(zhi))總電(dian)流(liu)(有效值(zhi)(zhi))、有功功率(平均值(zhi)(zhi))測量(liang)精(jing)度(du):±3%

 

21

三(san)倍頻(pin)電壓發生器

電(dian)壓(ya)互感器(qi)耐壓(ya)試(shi)驗(yan)

電壓范圍(wei):0-240V 容量:5KVA

 

22

發電(dian)機轉子交流(liu)阻抗(kang)測試(shi)儀

阻抗測量

準確(que)度(du):0.2

 

23

電機(ji)短路測試儀

 

 

 

24

蓄電(dian)池恒流(liu)放電(dian)負載測試儀

蓄(xu)電池恒流放(fang)電測量

電流精度:0.5%

 

25

接(jie)地(di)引(yin)下線導(dao)通測試儀

測(ce)量(liang)接地(di)引下線

準確度:±5%

 

26

接地電阻測試(shi)儀

變(bian)電(dian)所內使用

準(zhun)確度:±5%

基(ji)波的抗干擾電流不超(chao)過50mA

27

電纜故障測試儀電纜路(lu)徑儀

電纜故障探測(ce)

大誤差:±10m 測量誤(wu)差:±1m

 

28

高(gao)壓(ya)核相儀

高壓線路相位(wei)核定

 

 

29

自動(dong)直(zhi)流微(wei)安表

微電(dian)流測量

0-200-2000uA 準(zhun)確度:0.5級(ji)

 

30

鉗形電(dian)流表

電(dian)流測量

 

 

31

紅外熱像(xiang)儀

紅外測溫

靈(ling)敏度:0.1

推薦配置

32

點溫儀

紅外測(ce)溫

準確度(du):1%

推薦配置

 

110KV發(fa)、供電系統繼保測試及(ji)高電壓試驗設備的裝置

序號(hao)

試驗設備

試驗項目

技術指標(biao)

參考

1

微機繼電保護測試儀(單相)

各種常規單相試驗

AC:0-10A0-100A

DC:0-1500mA0-5A

0-100V   0°-360°

能模擬110KV及以下電壓等(deng)級試驗

2

微機繼電保護(hu)測試(shi)儀

(三(san)相)

微(wei)機型等復(fu)雜保護試驗

三(san)相電流:3×(0-30A,

四相電壓(ya):4×(0-120V

7對開入+三對開出,

帶載功率:5A:≥75VA 30A:400VA

輸出時(shi)間:<10A:連續輸出 20A>6030A:>10秒表(biao) 精度:0.2

滿足DL/T624-1997要求

3

模擬式兆歐表數(shu)字式兆歐表

絕緣電(dian)阻測量

500-2500V 10000MΩ

短(duan)路電流不小于2mA

4

直流高壓發生器

直流(liu)耐(nai)壓和(he)直流(liu)泄漏測(ce)量

200KV/2mA

 

波(bo)紋系數不大(da)于1%

5

試驗變壓器、控制臺、調壓器

工(gong)頻高壓試驗裝置(zhi)

25KVA/150KV

波紋失真(zhen)度(du)小于5%

6

變壓器直(zhi)流電阻測試(shi)儀

變壓器直(zhi)流電(dian)阻測(ce)量

1A  1mΩ-200Ω 0.2

測(ce)量(liang)電(dian)流(liu)根據變壓(ya)器容(rong)量(liang)確定

7

變壓器變比(bi)測試(shi)儀

變(bian)壓器變(bian)比測試儀

測量范圍(wei):1-100 準確(que)度:0.2級(ji)

 

8

變(bian)壓器損耗參數測試儀(yi)

變壓器空負(fu)載(zai)短路(lu)試驗(yan)

測量準確度不小于0.5級(ji)

 

9

介質損耗(hao)測試儀或(huo)高(gao)壓(ya)電橋

介損(sun)及電容量(liang)測量(liang)

tgδ:±5% 電容電量:±3%

 

10

變(bian)壓器繞組變(bian)形(xing)測試儀

 

掃頻信號發(fa)生單元(yuan)頻率范圍(wei):1-10000KHz

高(gao)速信號采(cai)集單(dan)元(yuan)采(cai)樣(yang)速率:20MHz 精度:0.2

 

11

變(bian)壓器有載分接(jie)開關測試儀

變(bian)壓器(qi)有載調壓開關測(ce)試

時(shi)間測(ce)量范圍:0-250ms 準確度:±0.1%

電(dian)阻測(ce)量范圍:0.1-20Ω 準確度(du):±1.0%

 

12

回路電阻測試儀(yi)

導電(dian)回路(lu)接(jie)觸電(dian)阻測量(liang)

準確度:0.51uΩ-2mΩ

輸出電流(liu)不(bu)小于100A

13

高壓開關機械(xie)特性測(ce)試儀

高壓開關機械動作特性測量

準(zhun)確度:±0.1%

 

14

真空度測試儀

真空(kong)開關真空(kong)度測量(liang)

 

 

15

斷口(kou)耐(nai)壓試驗裝置

真(zhen)空開關斷口耐壓試(shi)驗(yan)

電(dian)壓測(ce)量準確度:3.0

 

16

絕(jue)緣油介電強度測試(shi)儀

絕(jue)緣油(you)介電強(qiang)度試(shi)驗

電(dian)壓測量(liang)準確(que)度:3.0

穩態測量準確(que)度:1.5級(ji)

17

絕緣(yuan)油介質損(sun)測(ce)試儀

油介質損耗測量

Cx:±0.5%  tgδ:±5%

溫度(du):±1

 

18

無局(ju)放變(bian)壓器

局放(fang)試驗

25KVA/150KV

 

19

局(ju)部(bu)放電檢測(ce)儀(yi)

局部(bu)放電測量

頻率(lv):10-300HZ 準確度:10

 

20

高壓分壓器測(ce)量系統(tong)

試驗(yan)電壓測(ce)量

準確度:AC 1.0 DC 0.5

 

21

互感(gan)器綜合特性(xing)測試儀(yi)

互感器變比、CT伏安特(te)性測試(shi)

準(zhun)確度:0.2

 

22

氧化鋅避雷器測試(shi)儀

氧化(hua)鋅避雷(lei)器測量

可(ke)測量阻性(xing)電(dian)流(峰值)、電(dian)容電(dian)流(峰值)總電(dian)流(有效值)、有功功率(平均(jun)值)測量精度:&plusmn;3%

 

23

三(san)倍頻(pin)電(dian)壓(ya)發生器(qi)

電壓互(hu)感(gan)器耐(nai)壓試驗

電壓(ya)范圍:0-240V 容量(liang):10KVA

 

24

發(fa)電(dian)機(ji)轉子交(jiao)流阻抗測試儀(yi)

阻抗測量

準確度:0.2

 

25

電機(ji)短(duan)路測試(shi)儀

 

 

 

26

蓄電池(chi)恒流放電負載測試儀

蓄電(dian)池恒流放電(dian)測(ce)量

電流精度:0.5%

 

27

接地(di)引下(xia)線導通測(ce)試儀(yi)

測量接地(di)引下線

準(zhun)確(que)度:±5%

 

28

接地電阻測試儀(yi)

變(bian)電所內使用

準確(que)度(du):±5%

基波的抗干(gan)擾電(dian)流不超過50mA

29

SF6微(wei)水儀

SF6微(wei)水(shui)測(ce)量(liang)

露點范圍(wei):-60-+20 精度:±1

 

30

SF6露點儀

SF6露點測(ce)量

露點范圍:-60-+20 精度:±1

 

31

SF6氣體泄漏檢測儀

SF6氣體泄漏測(ce)量

誤差不超過10%

 

32

高壓核相儀

高壓線路相位(wei)核(he)定

 

 

33

高(gao)壓標準電容器

電容量測量

tgδ:1×10-4

 

34

自動(dong)直流微安(an)表

微電流測量

0-200-2000uA 準確(que)度:0.5級(ji)

 

35

隔離(li)濾(lv)波器

 

 

 

36

鉗形電流表(biao)

電流(liu)測量

 

 

37

紅(hong)外(wai)熱像(xiang)儀(yi)

紅外(wai)測溫

靈敏度:0.1

推薦(jian)配(pei)置

38

點溫儀

紅外測(ce)溫

準確度:1%

推薦配置

 

220KV、500KV發、供電(dian)系統繼保測試(shi)及高(gao)電(dian)壓(ya)試(shi)驗設備的裝置

序號

試驗設備(bei)

技(ji)術規范

參考

1

微(wei)機繼電(dian)保護測試儀

(三(san)相(xiang))

三相(xiang)電流(liu):3×(0-30)A,

四相電壓:4×(0-120)V

開(kai)關量:7對開(kai)入(ru)+3對開(kai)出,

帶載功(gong)率:5A:≥75VA 30A:≥400VA

輸出(chu)時間(jian):<10A:連續輸出(chu) 20A:>60秒(miao)(miao)&nbsp;30A:>10秒(miao)(miao)表精度(du):0.2級(ji)

微機型(xing)等(deng)復(fu)雜保護

滿足DL/T624-1997要求

2

微機繼電保護測試(shi)儀

(六相)

六(liu)相電流:6×(0-30)A,

六(liu)相電壓:6×(0-120)V

開(kai)關量:8對(dui)開(kai)入+4對(dui)開(kai)出(chu),

帶(dai)載功率:5A:≥75VA 30A:≥400VA

輸(shu)出時間(jian):<10A:連(lian)續輸(shu)出 20A:>60秒 30A:>10秒表精度:0.2級(ji)

微機型等復雜保護

滿足DL/T624-1997要求

3

兆(zhao)歐表

用(yong)于測量(liang)一般(ban)設備的絕緣電阻:

額定電壓:500V 量程:0-50MΩ

額定電壓:100V 量程:0-1000MΩ或(huo)0-10000MΩ

用于吸(xi)收比或極化指數:

2500V 0-1000000MΩ 2mA以(yi)上 5000V ; 0-1000000MΩ 5mA以(yi)上

水內冷發電機(ji)測量表:

2500V 0-1000MΩ或0-10000MΩ 500V 0-1000MΩ或0-10000MΩ

數字式或整流(liu)式

數字(zi)式(shi)

4

直(zhi)流(liu)高(gao)壓發生器(qi)及測量系統(tong)

用于(yu)水內(nei)冷發電(dian)機試驗:額定電(dian)壓(ya):0-60KV輸出電(dian)流:500mA

用于10KV及以下電(dian)力電(dian)纜(lan)和氧化鋅避雷器試驗:額(e)定電(dian)壓(ya):0-60KV 輸出電(dian)流:2mA 波紋系數:>1%

用于35KV電纜和(he)氧化鋅避(bi)雷(lei)器試驗:

額定電壓:0-120KV 輸(shu)出電流:2mA ;波紋(wen)系數:>1%

滿足GB/T16927.21997要求

5

無局部放試驗裝置(zhi)(套)

50KVA/250KV包括隔離(li)變、濾(lv)波裝置、高壓準準電(dian)容器、試驗變壓器

局部(bu)試驗用

6

局部放電檢測儀

頻率(lv):10-300KHZ 準確度:±10%

局(ju)部放電(dian)測(ce)量(liang)

7

交流(liu)高(gao)壓試驗變壓器(套)

額定電壓:50KV、100KV、200KV 輸出容量:按試品容量選擇

滿足GB/T16927.21997要求(qiu)

8

諧(xie)振(zhen)耐壓(ya)成(cheng)套裝置(套)

額定電壓:50KV 輸出容量:按試品容量選擇(ze)

發電機工頻(pin)耐(nai)壓用

9

諧振耐壓成套(tao)裝置(套(tao))

額定(ding)電壓:150KV 輸出容量:按(an)試品容量選擇

交(jiao)流電纜耐壓用

10

高壓分(fen)壓器

測量(liang):峰值(zhi)、有效值(zhi)、直流電(dian)壓 量(liang)范(fan):0-200KV、0-100KV、0-50KV

準確(que)度:交(jiao)流1.0級,直流 0.5級

試驗電壓測量

11

變壓器直(zhi)流電阻測試儀(yi)

測量范圍:1mΩ-20Ω

測量電流(liu):≥1A

準確度:±0.2%

用于變壓(ya)器直(zhi)流(liu)(liu)電阻測量(liang);測試電流(liu)(liu),根據變壓(ya)器容(rong)量(liang)確(que)定。

12

變壓器變比測試儀

測量(liang)范圍(wei):1-5000 準確度(du):0.2級(ji)

變壓器變比測量用(yong)

13

介(jie)質(zhi)損(sun)耗測(ce)試儀或高壓電橋(qiao)

對(dui)于2-10KV試(shi)驗(yan)電壓(反接線)電容量范圍:10pf-50nf 準確(que)度:±3%  tgδ范圍:0.1-60% 相對(dui)誤(wu)差±1%

對于2-10KV試驗(yan)電(dian)壓(正接線(xian))

電容量(liang)范圍:10pf-50nf 準確度(du):±0.5%  tgδ范圍:0-100% 相對誤差±1%

對油(you)介(jie)損測量參數執行標準為GB5654-85;110KV及以(yi)上高壓電(dian)氣設備高電(dian)壓介(jie)損用(yong)

14

變壓器損耗參數(shu)綜合(he)測試儀

準確度:±0.2%

變壓器(qi)空短路試驗綜合參(can)數(shu)測量

15

變(bian)壓器繞阻變(bian)形測試(shi)儀(yi)

掃頻(pin)信號(hao)發生單元頻(pin)率范圍:1-1000KHz

高速(su)信(xin)號采集(ji)單元采樣速(su)率:20MHz 精(jing)度:0.2級

 

16

變壓器有(you)載分(fen)接開關(guan)測(ce)試儀

時(shi)間測量范圍(wei):0-250ms 準確度:±0.1%

電阻測量范圍:0.1-20Ω 準確度:±1.0%

變壓(ya)器有載(zai)調壓(ya)測試

17

絕(jue)緣油(you)介電強度測(ce)試儀(yi)

技術(shu)條件(jian)應(ying)符合(he)GB50786和DL429.991

穩態測量準確度:1.5級

18

高壓開關機械特性測試儀(yi)

能測(ce)量固有(you)分(fen)(合(he))時(shi)間(jian)、同期、剛分(fen)(合(he))速度及大分(fen)(合(he))速度 準確度:±0.1%

 

19

回路電(dian)阻(zu)測試儀

直流(liu)(liu)輸出電流(liu)(liu):≥100A或200A 測量范(fan)圍:0-19999u&Omega;小(xiao)分(fen)辨率:1×10-6Ω 相對誤差:±0.5%

能(neng)直讀電(dian)阻值(zhi)

20

SF6氣(qi)體密度繼電(dian)器測量儀(yi)

精度:0.5級 測量壓(ya)力(li)范圍:0-1.0Mpa ;測量溫度范圍:-3℃-+70℃ 校驗壓(ya)力(li)范圍:20℃時標準啞壓(ya)力(li)0.1-1.0 Mpa

 

21

三(san)倍頻電壓(ya)發生器

電(dian)壓(ya)范圍:0-240V 容(rong)量:5-10KVA

用于電磁(ci)型(xing)電壓互感器

22

真空度測試儀

 

 

23

接地(di)引下線導通測試儀

準確度:±5%

測量接地引(yin)下線

24

接地電阻測試儀

輸出電(dian)流:1A

基波(bo)(bo)(bo)濾波(bo)(bo)(bo)衰減應為52db, 使(shi)基波(bo)(bo)(bo)的干擾電流不超過50m,儀器的準確度:±5%

變電所內使用

25

電(dian)纜故障測試儀(包括(kuo)定(ding)點(dian)儀及路徑儀)

1.0-10kv高(gao)阻滑線電(dian)阻電(dian)纜故障探(tan)測儀 大誤差:±2%

2.電纜故障閃絡(luo)測(ce)量(liang)儀&nbsp;測(ce)量(liang)誤差:2-5m

3.聲測定(ding)點(dian)儀(yi) 大(da)誤差(cha):&plusmn;10m

4.電纜路徑儀(yi) 測量誤(wu)差:±1m

 

26

互感(gan)器綜合特性測試儀(yi)

準確度(du):0.2級(ji)

互感器變比CT伏安(an)特性測(ce)量

27

氧化鋅避(bi)雷(lei)器測試儀

可測量(liang)阻性電(dian)(dian)(dian)流(liu)(峰值(zhi)(zhi))、電(dian)(dian)(dian)容電(dian)(dian)(dian)流(liu)(峰值(zhi)(zhi))總電(dian)(dian)(dian)流(liu)(有效(xiao)值(zhi)(zhi))、有功功率(平均值(zhi)(zhi))測量(liang)精(jing)度:±3%

 

28

升流器

升流范圍:0-2500A或0-1000A

 

29

斷口耐壓試驗裝(zhuang)置

準確度(du):3.0級

真空開(kai)關斷口耐壓試驗(yan)

30

SF6微(wei)水(shui)儀

露點范圍:-60℃-+20℃ 精度:±1℃

SF6微水測量

31

SF6露點(dian)儀(yi)

露點范(fan)圍:-60℃-+20℃ 精度:±1℃

SF6露點測(ce)量(liang)

32

SF6氣體泄(xie)漏檢測(ce)儀

誤差不超過±10% 靈敏度(du)不低于1u1/1

SF6氣(qi)體(ti)泄漏測量

33

數字式電(dian)容電(dian)感測試儀(yi)

準確度:0.5級

 

34

發(fa)電機轉(zhuan)子交流阻(zu)抗測試儀(yi)

準確度:0.2級(ji)

阻(zu)抗測量

35

電機短路(lu)測(ce)試儀

 

 

36

蓄電池(chi)恒流放電負載測試儀

電流(liu)精度:0.5%

蓄電池(chi)恒流放電測(ce)量

37

紅外熱像儀

靈敏(min)度:0.1℃

供電(dian)公司及有(you)125MW及以上機組(zu)的發電(dian)廠配置

38

調壓升壓器

電壓(ya)范圍:0-2000V 輸出(chu)電流:20A

 

39

雙臂電橋

電(dian)壓范圍:1×10-6-22Ω 準(zhun)確度(du):0.2級

 

40

避雷(lei)器計數器測試儀

放電電壓:0-3000V 充電時間(jian)小于1分(fen)鐘

 

41

電壓互感器(3臺)

額(e)定電壓:6-35KV準確(que)度:0.2級

變壓(ya)器試驗用

42

電流互感器(qi)(3臺)

額定(ding)電壓:6-35KV 2500A/5A 準確度:0.2級

變(bian)壓器試驗(yan)用

43

交直流電壓(ya)表

測量范圍:0-150-300-600V 準(zhun)確度(du):0.5級(ji)

 

44

交直流(liu)電流(liu)表

測量范圍:0.5A、1A、2.5A、5A、10A

準確度:0.5級(ji)

 

45

交直流(liu)峰值電壓表(biao)

測量(liang)范圍:0-20-200-400V 準確度:0.5級(ji)

 

46

單相自耦調壓(ya)器(qi)

輸出電(dian)壓:0-250V 容量:1,3,5,10,20KVA

 

47

三(san)相自耦調壓器

輸(shu)出(chu)電壓:0-420V 容量: 3,9,15KVA

 

48

滑線電阻

1000&Omega;1A  500Ω2A  250Ω4A  5&Omega;20A

基波的抗干擾(rao)電流(liu)不超過50mA

49

無(wu)感(gan)電阻箱

0-9999.99Ω

 

50

直流毫(hao)伏(fu)表

測量范(fan)圍:0-75mV 準確度(du):0.5級

 

51

分(fen)流器

75A、100A、200A、300A、750A、1500A、2000A/75 mV 準確(que)度:0.2級(ji)

 

52

瓦特表

測量范圍:0-2.5-5A 0-75-150-300V 功率(lv)因素:1.0&nbsp;準確(que)度:0.5級

 

53

低功率因(yin)素瓦特表(biao)

測(ce)量范(fan)圍:0-2.5-5A 0-75-150-300V 功率(lv)因素:0.1-0.2準確度:0.5級

 

54

自動(dong)直流(liu)微安表

0-200-2000uA 準確度:0.5級

 

55

直流電壓表(biao)

測量范圍:0-3-15-30-150-300-600V 準確(que)度:0.5級

 

56

直流電流表(biao)

測量范圍:0-1.5-3-7.5-15-30A 準(zhun)確度:0.5級

 

57

示(shi)波(bo)器

采樣(yang)速率:100MHz

 

58

數字萬用表

測量范圍:交流(liu)(liu)電(dian)(dian)壓、直流(liu)(liu)電(dian)(dian)壓、交流(liu)(liu)電(dian)(dian)流(liu)(liu)、直流(liu)(liu)電(dian)(dian)流(liu)(liu)、電(dian)(dian)阻

 

59

頻率計

測(ce)量范(fan)圍:10-500Hz 輸入電壓(ya)范(fan)圍:30mV-300V 準確度:0.5級

 

60

相位表

測量范圍:0-360°分辨率:1°準確度:0.5級

 

61

高(gao)斯計(ji)

準(zhun)確度:0.5級

電(dian)廠(chang)配置

62

三相相序表

電(dian)壓(ya)范圍:50-500V

 

63

秒表

0-15min

 

64

點溫計

準(zhun)確度:1%

紅外測溫

65

溫度計

測量范圍:0-100%

 

66

溫度(du)計(ji)

測量范(fan)圍:-35℃-60℃

 

67

控制箱

按試驗變壓器容量(liang)配置(zhi)

帶明顯(xian)斷開點(dian)

68

隔離(li)變(bian)壓器(qi)

220V/220V 5KVA 380V/380V 20KVA

 

69

隔離濾波器

5-10KVA

 